Control Drawings - Stahl 9182 Serie Mode D'emploi

Transmetteur de température
Masquer les pouces Voir aussi pour 9182 Serie:
Table des Matières

Publicité

14.3 Control Drawings

Type 9182/**-**-**
Hazardous area:
Safe area:
The Temperature Transmitter Type 9182 is an associated apparatus as well as a nonincendive apparatus for installation in non-
hazardous, Class I, Division 2 or Zone 2 hazardous (Classified) Locations and provides intrinsically safe connections for one (or two)
field devices located in Class I, II, III, Division 1, Group A-G or Class I, Zone 0 [AEx ia] ] Group IIC, hazardous locations according to
NEC Article 504/505 as listed below.
Temperature Transmitter Type 9182/a0-5b-1c
a = numeral 1 or 2 for number of channels
b = numeral 0, 1, 3 or 9 for analog output
c = numeral 1 or 2 for number of contacts
Entity parameters for wiring configurations are as follows:
Type
V
OC
[V]
9182/*0-5*-1*
6.5
Notes:
1. Intrinsically safe apparatus may be switches, thermocouples, LEDs, RTDs or an FM Approved System or
Entity device connected in accordance with the manufacturer´s installation instructions.
2. For Entity concept use the appropriate parameters to ensure the following:
d V
V
or V
t
OC
d I
I
or I
t
SC
max
3. Electrical apparatus connected to an intrinsically safe system should not use or generate voltages > 250 V (U
4. Installation should be in accordance with Article 504/505 of the National Electrical Code, ANSI/NFPA 70 and ANSI/ISA RP 12.06.01
5. Use a general purpose enclosure meeting the requirements of ANSI/ISA S82.02.01 for use in non-hazardous or
Class I, Division 2, hazardous (Classified) locations.
6. Use an FM Approved Dust-ignition proof enclosure appropriate for environmental protection in Class II, Division 1,
Groups E, F and G; and Class III, hazardous (Classified) locations.
7. Each channel shall be installed within a separately shielded cable or a single cable with a separate shield for each channel.
8. These modules are to be mounted on DIN rail, DIN rail with pac-Bus (type 9194) or pac-Carrier (type 9195).
The field wiring in any case is connected to the IS pac device terminals.
9. Ambient temperature: -20 °C ... +70 °C (any mounting position)
169038 / 9182604310
2013-08-14·BA00·III·fr·10
Class I, II, III; Div. 1; Group A-G or Class I; Zone 0; Group IIC/IIB Hazardous Locations
Non-hazardous, Division 2 or Zone 2 Hazardous (Classified) Locations
L
o
I
P
CL.I, Div.1, A,B /
CL.I, Div.1, C-G /
SC
O
Zone 0, GP.IIC
[mA]
[mW]
19.7
32
90 mH
t C
C
, C
+ C
max
o
a
i
leads
t L
L
, L
+ L
o
a
i
leads
2007
04.05.
Einsiedle
r
Kaiser
(only 9180/2)
L
C
o
o
CL.I, Div.1,A,B /
Zone 0, GP.IIB
Zone 0, GP.IIC
330 mH
25 µF
d P
P
o
i
Certification drawing
Temperature Transmitter
Type 9182
91 826 01 31 1
Transmetteur de température
Série 9182
C
o
CL.I, Div.1, C-G /
V
I
max
max
Zone 0, GP.IIB
570 µF
-
-
).
max
none
1 of 1
FM
Divers
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
19

Publicité

Table des Matières
loading

Table des Matières