EMC: en 61326-1 This product complies with requirements of the following
european Community Directives: 89/336/eeC (electromagnetic Compatibility) and
73/23/eeC (low Voltage) as amended by 93/68/eeC (Ce Marking). however, electrical
noise or intense electromagnetic fields in the vicinity of the equipment may disturb the
measurement circuit. Measuring instruments will also respond to unwanted signals that
may be present within the measurement circuit. Users should exercise care and take
appropriate precautions to avoid misleading results when making measurements in the
presence of electronic interference.
Electrical (23 °C ± 5 °C) < 75% Rh
AC Voltage
Voltage
600.0V
CMRR :
input impedance:
Crest factor:
ACV AutoVA
TM
Threshold:
DC Voltage
Range:
Accuracy:
nMRR :
CMRR :
input impedance:
TM
DCV AutoVA
Threshold:
PEAk-rms HoLD (ACA & ACV only)
Response: 65ms to 90% rdg
ohms
Range:
Accuracy:
open Circuit Voltage :
Audible Continuity tester
Audible threshold: between 10Ω and 300Ω.
Response time: 250μs
ACA Current (Clamp-on)
Range
50hz to 60hz
45 to 50hz, 60 to 500hz
500hz to 3.1khz
> 60 dB @ DC to 60 hz, Rs = 1 kΩ
2 MΩ, 30 pf nominal
< 2.3 : 1 at full scale; < 4.6 : 1 at half scale
30VAC (40 to 500 hz) nominal
600.0 V
± (0.5% rdg + 5d)
> 50 dB @ 50/60 hz
>120 dB @ DC, 50/60 hz, Rs = 1 kΩ
2 MΩ, 30 pf nominal
2.4VDC nominal
000.0 to 999.9 Ω
± (1.0% rdg + 6d)
0.4VDC typical
12
Accuracy
± (0.5% rdg + 5d)
± (1.5% rdg + 5d)
± (2.5% rdg + 5d)