Temperature
The values of the automatic switching refer to a battery
dependent control
temperature of 20° C. When using a temperature sensor at
(optional)
the battery II, these values vary as a function of the
battery temperature.
High temperature => lowering of the threshold values.
Low temperature => higher threshold values.
Application:
Parallel operation, buffer operation, general charging
operation
Temperature:
Ambient temperature of -25° C to +35° C. During
operation, the housing may heat up to approx. 75° C.
Cooling:
By convection
Implementation:
According to Association of German Electrotechnical
Engineers regulations and the provisions of the
Instrument Safety Act.
Design according
EN 60 335-1 / EN 55014-1 / EN 55014-2 / EN 61 000-3-2/3
to:
Test labelling:
Use
For charging batteries with a rated voltage 12 V and a
:
capacity of 70-200 Ah and for 12 V current distribution.
EVS 30/20-DS/IU
Use
For charging batteries with a rated voltage 12 V and a
EVS 30/30-DS/IU
:
capacity of 100-300 Ah and for 12 V current distribution.
Housing:
Aluminium, bright/painted red, ventilated
Length:
302 mm (without legs)
Width:
173 mm (without legs)
Height:
100 mm
Weight:
3 kg (30 N)