Timer function

Set-up (and use) is only possible if plug-in thermostat is switched on by the „
and the temperature is displayed in the lower row.
Selecting operating mode
Refer to the corresponding chapter of these operating instructions.
Switching the timer on/off
• In order to switch the timer on or off, briefly press the „P" key.
• Once the timer is switched on, the symbol „
the timer time bottom right.
Setting timer time and temperature limit
• Switch on the timer first as described above.
• Hold the „P" key for approx. 3 seconds until the timer time starts flashing.
• Set the timer time using the „+" or „-" key (1....99 hours). For quick adjustment, press and hold
down the corresponding key for longer.
• Briefly press the „P" button. The temperature limit value will flash.
• Use the „+" or „-" key to set the temperature limit value. For quick adjustment, press and hold
down the corresponding key for longer.
• In order to quit the set-up mode, briefly press the „P" key. Alternatively, wait for about 10 sec-
onds, without pressing any key. The timer time will stop flashing.
Function of the timer
Example:
The room temperature is e.g. 19 °C and you set the temperature of 25 °C and duration of
5 hours via the timer.
After the start of the timer, the thermostat will control the connected appliance according to the
measured room temperature for the next 5 hours.
Timer operation can be paused and resumed by the „
If the timer functions should be terminated, switch off the timer by the „P" key as described
above.
After expiry of the timer time, the plug-in thermostat will turn off the connected appli-
ance.
If the plug-in thermostat should operate in normal mode after that, switch the ther-
mostat („OFF" will appear on display) off and on again.
Resetting the plug-in thermostat
To reset the plug-in thermostat to factory settings, press briefly the recessed „Reset" key (on
the right below the „
" key) e.g. by a toothpick.
Function
„COOL" = cool mode
„HEAT" = heat mode
Timer

Care and Cleaning

Before cleaning the product, disconnect the appliance from the plug-in thermostat. Disconnect
then the plug-in thermostat from power supply by pulling it out of the mains socket.
Never use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since these
could damage the housing or even impair operation.
Use a dry, lint-free cloth to clean the product.
Disposal
Electronic devices are recyclable material and do not belong in the household
waste. Dispose of an unserviceable product in accordance with the relevant statu-
tory regulations.
" will appear on the display bottom left, and
" key.
Factory settings
25 °C
20 °C
2 hours
Heating Mode: 16 °C
Cooling Mode: 28 °C

Technical Data

" key
Operating voltage ......................... 230 V/AC, 50 Hz
Connection power ......................... Ohmic load: max. 3680 W (230 V/AC, 16 A)
......................................................
Devices with mainly resistive load are, e.g., light bulbs, heaters, etc.
Powered devices with inductive load are, e.g., engines, control gears, conventional
transformers, energy-saving bulbs, etc.
Switch type ................................... Relay (single-pole)
Temperature adjustment range ..... Heat mode: +5 °C to +30 °C
......................................................
Accuracy ....................................... ±/0.5 °C
Backup rechargeable battery ........ yes, built-in permanently (NiMH, 2,4 V); charging time
Socket with child protection .......... yes
Ambient conditions ....................... Temperature 0 °C to +40 °C, air humidity 0% to 90% rela-
Dimension ..................................... 129 x 55 x 78 mm (H x W x D, including plug)
Weight .......................................... 170 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE.
Inductive load: max. 460 W (230 V/AC, 2 A)
Cooling mode: +10 °C to +35 °C
ca. 14 h, back-up time ca. 30 days
tive, not condensing
15621Q1