BIP LD2-T017-04-BP _ _ / BP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.7
System commands
Index
Subindex
Hex. Dec. Hex. Dec.
0002 2
00
0
Tab. 6-8:
System commands
6.8
Profile-specific parameters
Index
Parameters Sub-index Parameters
Hex. Dec.
003A 58
Teach-In
channel
003B 59
Teach-In
status
003C 60
Set Point
value (BDC1)
003D 61
Switch Point
configuration
(BDC1)
003E 62
Set Point
value (BDC2)
003F 63
Switch Point
configuration
(BDC2)
4000 16384 Set Point
value (BDC3)
4001 16385 Switch Point
configuration
(BDC3)
Tab. 6-9:
Profile-specific parameters
www.balluff.com
Parameters
Data
Access Value
format
System
UINT8
Write
command
only
Hex. Dec.
00
0
00
0
01
1
Setpoint SP1
02
2
Setpoint SP2
01
1
Switchpoint logic
02
2
Switchpoint mode
03
3
Switchpoint
hysteresis
01
1
Setpoint SP1
02
2
Setpoint SP2
01
1
Switchpoint logic
02
3
Switchpoint mode
03
3
Switchpoint
hysteresis
01
1
Setpoint SP1
02
2
Setpoint SP2
01
1
Switchpoint logic
02
2
Switchpoint mode
03
3
Switchpoint
hysteresis
Comments
range
0x4B
Teaching
Temporarily saves the current
Slmin/
position as Slmin.
Slmax
0x4C
Saves the current position as
Slmax.
0x4D
Applies the Slmin/Slmax values.
0x4F
Deletes the temporarily saved
values.
0x4E
Resets all settings of the selected
channel to the default values.
0x82
Reset
Reset to factory settings
Data
Access
Value range
format
Hex.
UINT8
Read/
00
Write
01...03
UINT8
Read only See Smart Sensor Profile
(www.io-link.com)
UINT16
Read/
00...0FFF 0...4095
Write
0
UINT8
Read/
00...01
Write
00...01
UINT16
≥0013
UINT16
Read/
00...0FFF 0...4000
Write
0
UINT8
Read/
00...01
Write
00...01
UINT16
≥0013
UINT16
Read/
00...0FFF 0...4095
Write
0
UINT8
Read/
00...01
Write
00...01
UINT16
≥0013
Comments
Dec.
0
BDC1
(default)
1...3
BDC1...BDC3
0
Functionally not
supported
0...1
0...1
≥19
Smallest
hysteresis value
0
Functionally not
supported
0...1
0...1
BDC activated
≥19
Smallest
hysteresis value
0
Functionally not
supported
0...1
0...1
≥19
Smallest
hysteresis value
english
13