Oase Skimmer 250 Notice D'emploi page 6

Masquer les pouces Voir aussi pour Skimmer 250:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- English -
Switching on, switching off (C)
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug prior to reaching into the water and commencing work.
The unit switches on automatically when power connection is established.
Switching on: Plug the power plug (10) into the socket.
Switching off: Disconnect the power plug (10).
Pump removal (D-G)
Remove the retaining basket (11). Remove the brace (12) from the pump holder (13). Remove the Tradux wall
leadthrough (F) to be able to take out the power cable. For this purpose, only loosen the four M5 Allen screws, then
pull the entire unit out of the leadthrough tube (15). Remove the Allen screws as well as the rear (16) and front (17)
retaining plates together with the sealing insert (14). Pull the connection cable through the leadthrough tube (15). Pull
the pump (18) out of the pressure piece and remove from the floating body (5).
Important: When reassembling the Tradux wall leadthrough (F), ensure that the front (17) and rear (16) half shells of
the retaining plates are arranged at a 90° offset in relation to each other.
Cleaning (D-E)
Disconnect the power plug (10) prior to starting cleaning work!
Empty out the retaining basket (11) at regular intervals, clean with clear water, if necessary.
Clean the floating body (5) and the pump (18), as required, with clear water using a soft brush.
Malfunction
Malfunction
Pump does not start
Pump does not deliver, insufficient delivered
quantity
Skimmer housing too high in the water
Insufficient cleaning effect
Pump switches off after a short running period
Storage/Over-wintering (H)
Take the unit out of operation when temperatures below zero are to be expected. Take the unit out of the water and
remove pump (18).
Clean pump (18) under running water, store immersed in a water filled container and frost protected. Do not immerse
the power plug in the water! Ensure that the storage place is inaccessible to children.
Store the floating body (5) in a dry and frost protected place.
6
Cause
No mains voltage
Retaining basket clogged
Skimmer flap jammed or sluggish
Skimmer flap jammed or sluggish
Excessively soiled water
Water temperature too high
Remedy
Check mains voltage
Clean, check supply lines
Clean retaining basket
Clean skimmer flap bearing, ensure that skim-
mer flap operates freely
Clean skimmer flap bearing, ensure that skim-
mer flap operates freely
Clean pump
Note maximum water temperature of 95°F
(+ 35°C)

Publicité

Table des Matières
loading

Table des Matières