Periodic Checks; Problems, Causes And Solutions - REPA MATIC Serie Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PERIODIC CHECKS

AFTER THE FIRST 6-12 MONTHS, AND THEN EVERY 6-12 MONTHS:
Clean the salt container following the procedure hereunder:
• Remove the remaining salt from the bottom;
• Clean all the walls of the container from muddy, oozy or dry salt deposits;
• Rinse several times with running water using a disinfectant and a sponge;
• Rinse again, add the same quantity of water and then add the salt
Periodically clean the washable cartridge of the pre-filter by removing all impurities from the bottom and from the surface
of the cartridge. It is sufficient to use running water.
TROUBLE SHOOTING

PROBLEMS, CAUSES AND SOLUTIONS

PROBLEMS
Regeneration starts at a wrong time
The programmer stops during the
regeneration cycle
The programmer does not regenerate
automatically or when the start up
button is pushed
The programmer does not regenerate
automatically but only by pushing
the start up button
Lack of softened water between
two regenerations
CAUSES
Timer set up incorrectly
Burnt out engine
Power supply failure
Incorrect voltage or frequency
The camshaft is blocked
Excessive supply pressure
Power supply disconnected
Damaged or burnt out engine
Burnt out feeder
Damaged or burnt out timer
Too many days between scheduled
regenerations
Burnt motor
Internal gear broken
Incorrect regeneration
Polluted resins
Wrong set-up of the quantity of salt
Mixing screw too tightly fastened
External by-pass open
Obstructed output
SOLUTIONS
Set up the timer
Replace
Check connection
Check the right voltage or frequency
Remove damaging bodies from the valve
or from the camshaft
Install a pressure regulator
Connect
Replace engine
Replace feeder
Replace timer
Reduce amount of days between
regenerations
Replace motor
Replace gear
Repeat the regeneration cycle checking
that the correct amount of salt is
provided
Wash or replace resins
Check and set up again
Unfasten and check hardness
Close by-pass
Clean output
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Matic 5Matic 8Matic 12Matic 16Matic 20

Table des Matières