Control Buttons - Klein Tools LAN Scout Jr. 2 Manuel D'utilisation

Masquer les pouces Voir aussi pour LAN Scout Jr. 2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Presses of less than about 1 second (short press) and more than
1 second (long press) are recognized differently:
1. Power / Back light button: Short press: First short press turns unit on.
Press the power button second short press turns backlight on. Any
repeat of short press turns backlight on or off. Long press (greater than
2 seconds) of power button turns unit off. "OFF" will display as unit is
powering down.
2.
Cable testing (short press): With the LAN Scout™ Jr. 2 on, short press of the
test button initiates test. Loop mode, continuous test, is default setting. To turn
off Loop Mode, long press the test button. **
3. Toning: Starting with the LAN Scout™ Jr. 2 on, a short press of the tone
button will cause the LAN Scout™ Jr. 2 to tone in the low (Lo) frequency
mode on the first conductor wire. A second short press will transmit the
Lo tone on the second conductor wire. Repeated short presses will cycle
through toning on each individual conductor wire, and then each mated
pair and then all 8-conductor wires. The mode and wires toned on will
be displayed.
A long press of the tone button will cycle the tone from the low frequency
(Lo) to the high frequency (Hi) and to the warble cycle (Hi and Lo
intermittently). In test mode, the LAN Scout™ Jr. 2 will automatically power
off 10 minutes after last time test button is pressed. In tone mode, the
tester will turn off automatically 60 minutes after the last button press or
by exiting to mode select with a long press.
** Loop Mode assists in testing for intermittent problems. A test occurs every 2
seconds with no need to press the test button. Loop Mode on is default. To turn
Loop Mode off, long press the test button.
Testing continuity on terminated or installed RJ45 terminated cable (FIG 1 and 2):
1. Connect one end of the cable under test to the RJ45 shielded port located
on the top of the main tester. If testing a wall port, connect a known good
patch cable from the wall plate to the shielded RJ45 jack on the top of the
main tester.
2.
Connect the other end of the cable under test to the RJ45 shielded jack on the
testing remote. If testing a wall port, connect a known good patch cable from
the wall plate to the shielded RJ45 port on the testing remote.
3. Press the power button on the keypad to turn the tester on.
4. Press the test button on the keypad to begin the test.
5.
Interpret the results of the testing using the wiring and display examples below.
* NOTE the remote can be removed or stored on tester during testing.