ecofort ecoQ 9L steady Mode D'emploi page 71

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

71
Laundry Mode
This mode is ideal for creating a great environment for drying clothes. The unit will work for 8 hours
continuously with the desired humidity set at 40% before resting for 30 minutes. The unit will then check
the humidity of the room. If it is above 40% the unit will work for another 8 hours before repeating the
process. If the humidity of the room is found to be below 40%, the unit will rest for another 30 minutes
before rechecking the humidity of the room. The LED above the button is lit when Laundry Mode is
selected.
Humidity Button
This Allows the user to select the desired humidity for the room. The button should be repeatedly pressed
to cycle between the different options CO ( Continuous Mode ), 40%, 50% 60% or 70% RH.
Please Note: After 8 hours of the heater running continuously, the unit will rest for 30 minutes before
resuming the previously selected operation.
Timer Button
With the unit Turned On – Repeatedly press the Timer button to select in how many hours time you
require the machine to turn off. The number of hours is displayed on the Display Window.
With the unit Turned Off - Repeatedly press the Timer button to select in how many hours time you
require the machine to turn on. The number of hours is displayed on the Display Window.
The timer can be deactivated once set, by repeatedly pressing the timer button until 00 is shown on the
Display Window.
SMART Mode
This mode ensure minimum human intervention and maximum savings. Smart mode sets the desired
humidity for the unit to 55% RH which is the recommended humidity for normal households, and adjusts
the fan speed depending on the current humidity of the room, following the table below.
Above 70%
Between 55% and 70%
Less than 55%
Air purification Mode
This mode runs the fan without dehumidifying the air. This is great for purifying the air when the desired
room humidity has been reached, especially when the optional HEPA filter is installed. If using a HEPA
filter while dehumidifying please note that performance of the unit may be reduced by 10%.
Unit will run in TURBO mode
Unit will run in Sleep Mode
Unit stops for 30 minutes before rechecking
rooms humidity. Will not restart until humidity is
above 55%

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecoq dryair 12lEcoq dryair 20l

Table des Matières