empfangen wird (HF-Busy). Wird der Funkcode des Senders verändert oder soll ein weiterer Handsender auf den Empfänger wirken,
ist zu beachten, dass der Empfänger auf den eingestellten bzw. neuen Funkcode programmiert werden muss !
Sollen mehrere Sender betrieben werden, kann der gelernte Funkcode über die TRI-DIP-Schalter in allen Sendern gleich eingestellt
werden, so dass die Anzahl der einsetzbaren Sender unlimitiert ist.
7
Technische Daten
Relais
Arbeitsfrequenz
Ausgang
Schaltleistung
Antenne
Spannungsversorgung
Stromverbrauch
Arbeitstemperatur
3-Channel Radio Receiver
Please read carefully!
These operating instructions form an integral part of this product and contain important information on how to commission, install and
operate it. They must be taken into consideration and given to the end user or other third party when the installer hands over the
product. These operating instructions must be retained for future reference.
Damage resulting from abuse or misuse is not covered by warranty. The manufacturer accepts no warranty for consequential losses
that may result directly or indirectly from use of this equipment. Any changes or modifications not expressly approved by the party
responsible for compliance could void the user´s authority to operate the equipment.
The product meets the requirements of the current European and national guidelines for electromagnetic compatibility. Conformity has
been established and the relevant statements and documents have been deposited at the manufacturer.
1
Mode of operation
Receiver SHR-7 L3 verifies coded radio frequency signals sent by corresponding transmitters and operates relay outputs on receipt of
a correct signal. The rated current for each relay is 6 A / 230 VAC maximum.
It should be noted that for applications that could put human life at risk, by using radio connection there is always
present a potential hazard due to extraneous disturbances.
The Operating Instructions need to be followed at all times.
2
Safety Precautions
Ensure that the product is isolated from any power supply before opening. Opening and installation of the product
must be performed only by a qualified electrician.
Further safety precautions
Every applicable regulations and standards have to be observed, in particular VDE0100, VDE0550/0551, VDE0700, VDE0711 and
VDE0860. The use of solid cables for connection is recommended since terminal design does not incorporate stress relief. The
product corresponds to Safety-Class II (without protective earth terminal) according to VDE0700, IEC335EN60335.
For commercial use, compliance must be made with the recommendations and instructions of the responsible regional/national
authorities.
For use in public institutions, schools, clubs and do-it-yourself workshops the operation of this product has to be supervised by
qualified personnel.
We do not assume any warranty and liability for personal or material damages caused by incorrect application or by failure to follow
these operating instructions.
For reasons of safety and conformity (CE) it is not permitted to modify or change parts of the product.
Electrical devices should be out of reach of children. Please be extra careful if children are around.
Opening and installation of this product has to be performed by authorised electricians only.
If you have not the corresponding expertise, ask qualified specialists or workshop for installation and commissioning. This product
and connected devices can be damaged as a result from inappropriate installation, connection or operation. Furthermore, this could
lead to other damages e.g. short circuit, fire or electric shock.
The product must not be installed or used in places where a risk of explosion may exist.
Do not touch antenna connectors with live parts.
The product should only be used in a case adequate for mains-voltage if applied!
The Relay Board is a state-of-the-art product. However, there is a risk of danger if installation or operation is performed by
unqualified personnel
If the relay contacts switch mains power supply, the electronics has to be operated in a corresponding installation casing.
Attention. Extreme danger!
When opening the product, live components may be touched. Isolate SHR-12 L4 from the mains power supply before
opening. Ensure that all connected devices and components are also disconnected from the mains-power supply.
230V AC / 6A oder 30V DC / 5A
433,92 MHz
3 potentialfreie Wechselkontakte
230V AC / 6A oder 30V DC / 5A
λ/4-Drahtantenne
230V / 50 Hz
ca. 15 mA (< 4 W)
o
-20
C bis +65
Operating Instructions
- 3 -
o
C
(D –
GB
F)