Lighting
•
Depending on your needs you can turn the lighting on or off. The light switch is located
on the front next to the thermostat.
Automatic defrosting
Defrosting takes place every four hours and lasts 15 minutes. During this time, the yellow
LED defrost indicator is lit on the right side of the thermostat.
User information
•
The inserted shelves can be mounted at different heights. They should be
placed at the height of the beverage packaging in order to make optimum use
of the interior capacity.
•
Stored beverages should be placed at a sufficient distance from each other to ensure
sufficient air circulation inside the unit. Too little space makes it difficult to obtain the
cooling effect.
•
To minimize the loss of cooling, the door should be opened for the shortest possible
time. Additionally, do not open the door too often.
•
In the case of an unexpected power failure, avoid when possible opening the door to
prevent the loss of cool air.
•
After a power failure or removal from the outlet, do not connect the device to
the mains power for at least 5 minutes.
6. Cleaning and maintenance
6.1 Safety advice
o Before beginning with repair or cleaning works make sure the device has been
disconnected from power socket (pull the power plug!!!) and has cooled down.
o Do not use any acid agents and make sure no water ingresses the device.
o To protect yourself from electric shock, never immerse the device, its cables and the
plug in water or other liquids.
CAUTION!
The device is not suited for direct washing via water jets. Therefore, you must not
use any kind of pressure water jet for cleaning the device!