STEP THREE – INSTALL RO FILTER ASSEMBLY
1. Select easily accessible area under sink to mount system manifold.
Note: Allow 4-6" clearance below the filter to the floor to allow ample space for filter changes.
2. Remove shroud from manifold and set aside.
3. Mark holes for mounting screws using built-in bracket on back of manifold.
4. Drill two pilot holes for mounting brackets using 1/8" drill bit.*
5. Insert mounting screws into the wall leaving approximately 3/8"
of each screw exposed.
6. Hang manifold on mounting screws.
*
!
CAUTION
STEP FOUR – INSTALL WATER STORAGE TANK
1. On the nipple on top of the tank, apply 4-6 wraps of Teflon
2. Hand-tighten the tank connector onto the tank
nipple 3-4 times. Note: do not cross-thread or over-tighten.
3. Using mount stand, place tank next to system assembly.
Use caution not to drill into anything beyond the cabinet wall.
®
tape.
6
H
Teflon® Tape