RO400 – SYSTEM CONFORMS TO NSF
STANDARD 58 FOR SPECIFIC CLAIMS.
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT
use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before and after the system. Systems
certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
2. Operating Temperature:
3. Operating Water Pressure:
4. pH 2 to 11
5. Maximum Iron present in incoming water supply must be less than 0.2 ppm.
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in
water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI
58. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations
of 0.05 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies
containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic.
Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the
Arsenic Facts section of the Performance Data Sheet for further information.
Arsenic (Pentavalent)
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent)
Chromium (Trivalent)
Copper Reduction
Cysts
Fluoride Reduction
Lead Reduction
Radium 226/228
Selenium
TDS
Turbidity
Recovery - 34.09%
Depending on water chemistry, water temperature, and water pressure, Aerus Water Systems production and performance will vary. Efficiency rating means the percentage of the influent
water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage. Recovery rating means the percentage
of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the
storage tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
WARNING: This product contains chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm. For more information:
www.aeruswater.com/prop65
A copy of the certificate by which the California Department of Public Health has
granted certification of the water treatment device.
Aerus, LLC – 5420 LBJ Freeway, Suite 1010, Dallas, TX 75240 • www.aerushome.com
Maximum: 100°F (40.5°C)
Maximum: 100 psi (690kPa)
% Reduction
97.6%
96.6%
98.7%
96.4%
98.5%
99.3%
>99.99%
94.5%
99.0%
80.0%
97.3%
95.9%
99.1%
Daily Production Rate - 27.17 GPD
Minimum: 40° (4.4°)
Minimum: 40 psi (2.8kg/cm2)
Inf. challenge
concentration
mg/L
0.05±10%
10.0±10%
0.03±10%
0.3±10%
0.3±10%
3.0±10%
minimum 50,000/mL
8.0±10%
0.15±10%
25pCiL±10%
0.10±10%
750±40mg/L
11±1mg/L
Efficiency - 21.69%
Seller _______________________________________ Date ________________
Buyer ______________________________________ Date ________________
12
Max Allowable
concentration
mg/L
0.010 mg/L
2.0
0.005
0.1
0.1
1.3
N/A
1.5
0.010
5pCiL
0.05
187
0.5NTU