Installation
Note: The programming orders are transmitted by the above
signals, measured in relation to neutral.
Respect the direction of connection:
BROWN = LIVE,
BLUE or GREY = NEUTRAL,
BLACK = PILOT WIRE
The black wire must NEVER be connected to an earth
terminal or to the GREEN / YELLOW wire.
Mode
Comfort
Eco
Frost protection
Heating off
Conf. -1 °C
Conf. -2 °C
195279_s2_s1_3663602436386_GOODHOME_A5_IM_Multi_V06.indb 51
195279_s2_s1_3663602436386_GOODHOME_A5_IM_Multi_V06.indb 51
Signal to be transmitted
Measurement in relation to neutral
0 Volt
230 V
115 V negative
115 V positive
230 V / 3 s
230 V / 7 s