5.6 Elapsed time meter (Option „V")
If the device is equipped with option „V" go ahead like described under 5.5. In addition
the following registers are displayed:
FSZ
Activation time in hours since last reset
GFSZ
Total activation time since start of operation (not resetable)
Alarm message
In case of jammed coin caused by a cramped cash box „Fehler" is displayed.
Reset the device by pushing the „Betrieb" button longer.
5.7 Multiple coin validator (Option „O")
Option „O" is an electronical coin validator programmed for standard Euro coins (0,10;
0,20; 0,50; 1,00; 2,00 €) and tokens. The insertable Euro amount can be set in menu
„Münzen" as mentioned in 4.2. (The tokens are available under item no. 2070 for WMA).
6. Technical data
6.1 Technical data ZMZ 0205
Voltage
Consumption
Switching power
Protection category
Dimension (WxHxD)
Weight
6.2 Technical data ZMZ 0215
Voltage
Consumption
Switching power
With contractor
Protection category
Dimension (WxHxD)
Weight
7. Maintenance
The devices are maintenance-free. Only the coin slot should be cleaned with a brush
time-to-time.
NZR – Ihr Partner für Energiemessung
230 V ~ 50 Hz
2 VA
max. 10 A (16 A at AC 1)
min. 20 mA (relay „ short-circuited" with noise suppression capacity)
IP 31
185 x 238 x 150 mm
ca. 3,0 kg
230 V ~ 50 Hz
3,6 VA
max. 10 A (16 A at AC 1)
min. 20 mA (relay „ short-circuited" with noise suppression capacity)
3x 20 A (3x 20 A at AC 1)
IP 31
185 x 238 x 150 mm (wall mounted)
235 x 280 x 165 mm (flush mounted)
ca. 3,0 kg
17