CLEARANCE TO COMBUSTIBLES
Sides....................................0 mm 0 inches
Floor.....................................0 mm 0 inches
Top........................................0 mm 0 inches
ELECTRICAL CONNECTION
A 15 AMP, 120 Volt, 60Hz circuit with a properly grounded
outlet is required. Preferably, the fireplace will be on a
dedicated circuit. Other appliances on the same cir-
cuit may cause the circuit breaker to trip or the fuse to
blow when the heater is on operation. The unit comes
standard with a 6' (1828mm) long three wire cord exit-
ing from the rear of the fireplace. Plan the installation
to avoid the use of an extension cord. If an extension
cord must be used, it must be a minimum 14 AW G
three wire with grounding type plug connector and rated
no less than 1900 W atts. The cord shall not be more
than 20 feet in length.
WARNING: Disconnect power before
attempting any maintenance or clean-
ing to reduce the risk of fire, electri-
cal shock or personal injury.
REPLACING LIGHT BULBS
This fireplace uses four clear 120 Volt, 60 Watt,
E-12 socket base light bulbs (small base, chan-
delier candle type). The 60 Watt bulbs are located
under the log set/ember bed. For convenience, if
one of the bulbs burns out, it may be a good idea
to replace all of the light bulbs.
1. Turn off power to the unit by unplugging the power
cord.
2. Let fireplace cool if it has been operating.
3. Remove the two screws on the top corner of screen.
Pull the screen upward slightly, and then pull out.
SERVICE INSTRUCTIONS
WARNING: Electrical outlet wiring
must comply with local building
codes and all other applicable
regulations to reduce the risk of
fire, electrical shock and injury.
WARNING: Do not use this fire-
place if any part of it has been un-
der water. Immediately call a quali-
fied service technician to inspect
the fireplace and replace any part
o f t h e e l e c t r i c a l s y s t e m i f
necessary.
ELECTRICAL SPECIFICATIONS
Voltage:
Total Amps:
Total Watts:
Heater Rating:
4. Remove the four screws that secure the log set/em-
ber bed in position.
5. Remove log set / ember bed and grate assembly.
6. Examine the bulb(s) to determine which bulbs need
to be replaced.
7. W hile holding the socket, unscrew defective bulb(s)
counterclockwise.
8. Install the new light bulb(s) by holding the socket
and screwing clockwise.
9. Reinstall the log set/ember bed, grate assembly
and screen. Follow the above procedure in reverse
order.
WARNING: Do not exceed 60
Watts per bulb. The use of
higher rated bulbs may result
in a fire causing property
damage and personal injury.
5
6
120 VAC, 60 Hz
11.5 Amps
1380 Watts
1200 Watts