Symptom
The PowerCenter is
not receiving power.

TROUBLESHOOTING

Possible Cause
The PowerCenter
is not turned On.
Too many devices are connected, causing
an overload, tripping the Thermal
Circuit Breaker.
Remedy
• Turn the PowerCenter switch on.
• Make sure the PowerCenter's AC power plug is plugged into
a properly grounded 120 volts (nominal) wall outlet.
• In some households, a wall switch may need to be turned on
to make the wall outlet active. Try turning on the light switches
located near the wall outlet.
• Press the PowerCenter Thermal Circuit Breaker button in to
reset. Please allow 10 minutes before attempting to reset. If
you reset too soon, the breaker will prematurely sense power
overload and not allow the PowerCenter to operate.
• If the Circuit Breaker continues to trip, try moving one or more
components to another PowerCenter. You may be drawing too
much current through one PowerCenter.