Note: insert a miniature fuse according to the technical data sheet, if specified.
Recommendation: check the unit for reliable function after a short cirucit
Core colours of ifm sockets: BN = brown, BU = blue, BK = black,
GN/YE = green/yellow.
*Output not short-circuit protected.
Short circuit can lead to immediate destruction of the unit.
Replacement of fibre optics
Remove the nut 1 and washer 2.
Carefully remove the rubber packing 3 from the connection piece.
Remove the faulty fibre optics 4.
Slide the supplied new nut 1, washer 2, packing 3 onto the replace-
ment fibre optics.
Insert the replacement fibre optics until the end into the hole of the
switching amplifier provided for this.
Press the packing 3 into the connection piece.
Secure the replacement fibre optics by tightening the nut 1.
4
3
2
1
Operation
Check the safe functioning of the sensor.
If in the application wrong switching occurs due to background radia-
tion (e.g. ovens), use units with higher switching temperatures.