The flame does not stay lit.
Make sure that:
It keeps the button pressed when it is rotating to position (
Continue pressing the button long enough for the flame to warm the safety
sensor (thermocouple).
The gas holes are not blocked in the area corresponding to the safety
sensor (thermocouple).
The flame goes out when the button is turned to the minimum position
( ). Make sure that:
The gas holes are not clogged.
There is no strong air current around the gas plate.
The minimum level has been adjusted correctly (see section Adjusting
valves).
The containers are not stable or do not sit well on the supports.
Make sure that:
The bottom of the kitchen containers are perfectly flat.
The containers are correctly centered in the support.
The supports are correctly placed and fitted on the gas plate.
The control buttons of the cooking zones do not turn smoothly
Over time, gas control valves can become dirty due to grease and accumulated
dust. In this case it will be necessary to access the valves to clean and grease
them, this cleaning and lubrication work must be carried out only by an
authorized Technician or the Official Technical Service.
Note:
If after these checks, observe anomalies or that the gas plate does not work
properly, contact the Official Technical Assistance Service or consult an
Authorized Installer.