Accuracy
Refer to "Specifications" for operating conditions and temperature
coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed
amount) at 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% to 80% relative humidity.
AC Voltage
Measurement Range
200.0 V
1000 V
Frequency Range: 50 Hz to 500 Hz
Input Impedance: 2 MΩ || 100 pF max.
DC Voltage
Measurement Range
200.0 V
1000 V
Input Impedance: 2 MΩ
Resistance
Measurement Range
200.0 Ω
2.000 kΩ
20.00 kΩ
200.0 kΩ
2.00 MΩ
20.00 MΩ
AC Current
Measurement Range
0.0 to 200.0 A
Frequency Range: 50 Hz to 60 Hz
Adjacent Conductor Influence: < 0.08 A/A
Continuity Beeper
Range
200.0 Ω
Open Circuit Voltage: 0.4 VDC typical
Audible Threshold: Between 50 Ω and 250 Ω
Diode Tester
Test Current
0.4 mA typical
Open Circuit Voltage: < 1.6 VDC typical
12
Accuracy
± (1.5% + 0.5 V)
± (1.5% + 5 V)
Accuracy
± (1.0% + 0.2 V)
± (1.0% + 2 V)
Accuracy
± (1.0% + 0.5 Ω)
± (1.0% + 0.002 kΩ)
± (1.0% + 0.02 kΩ)
± (1.0% + 0.2 kΩ)
± (1.0% + 0.002 MΩ)
± (1.9% + 0.05 MΩ)
Accuracy
± (3.0% + 0.3 A)
Accuracy
1.0% + 0.5 Ω
Accuracy (0.4 V to 0.8 V)
1.5% + 0.050 V