ing range. After adjusting the floodlight inclination, tighten
the mounting screws (4).
3) Connect the floodlight to the 230 V mains. For outside
mounting a weatherproof mains connection is compulsory.
Therefore, the connection must only be carried out by
autorized, skilled personnel.
5 Functional Test
The light radiated by the floodlight is within the infrared range
(wavelength 850 nm) and can therefore not be perceived by
the human eye. During operation only a reddish glowing of
the individual LEDs is visible. In quiet surroundings the inter-
nal fan can additionally be heard.
1) The floodlight must be connected to the mains voltage.
2) For the functional test with daylight, cover the light sensor
(2) – e. g. by black carton, darkening by a finger tip is not
always sufficient.
3) After the switch-on delay of a few seconds the floodlight
should switch on:
— the switching noise of the relay can be heard
— the fan noise can be heard
— the LEDs glow in reddish colour
4) With sufficient darkness the function can best be tested via
the camera.
6 Specifications
Power supply: . . . . . . . . . . . . . 230 V~/50 Hz/12 W
IR wavelength: . . . . . . . . . . . . 850 nm
Medium lifetime of the IR LEDs: approx. 6000 h
Radiation angle: . . . . . . . . . . . max. 65°
Range: . . . . . . . . . . . . . . . . . . max. 15 m
Safety class: . . . . . . . . . . . . . . IP 33
Ambient temperature: . . . . . . . -20 °C up to +60 °C
Dimensions (W x H x D): . . . . 95 x 100 x 160 mm
Weight: . . . . . . . . . . . . . . . . . . 1.3 kg
According to the manufacturer.
Subject to technical change.
All rights reserved by MONACOR
No part of this instruction manual may be reproduced in any form or by
any means for any commercial use.
INTERNATIONAL GmbH & Co. KG.
®
GB
11