Télécharger Imprimer la page

Cooper Lighting Solutions Streetworks LXT Instructions D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions – LXT/LXF Pole-Top Luminaire
N
otee:
These luminaires are designed for outdoor lighting
service, and should not be used in areas of
limited ventilation or in high ambient temperature
enclosures. Best results will be obtained if
installed and maintained according to the following
recommendations.
The LXT/LXF are designed to fit a 2-3/8" or 3"O.D.
pole top or vertical tenon.
N
otee:
These instructions do not claim to cover all details or
variations in the equipment, procedure, or process
described nor to provide directions for meeting
every possible contingency during installation,
operation or maintance. When additional information
is desired to satisfy a problem not covered
sufficiently for user's purpose. Please contact your
nearest representative.
INSTALLATION
LXT/LXF
1.
On a pole that is wired with electrical service lead
wires, pull electrical service lead wires through
sufficiently beyond pole-top to reach through fixture
fitter into base.
2.
Loosen captive cover retaining screw or latches and
open hinged cover fully.
3.
Remove all lens panels by pulling up and out of slotted
comer posts. When lens panels are not the same,
identify lens with window number located on housing
overhang for proper replacement after installation.
4.
Feed service lead wires through bottom of fitter into
base cavity. Place fixture on pole top (care must be
taken not to pinch service leads). For fixture with
asymmetric Iight pattern, locate the word "Streetside"
on the housing overhang. Position fixture on pole
so "Streetside" faces the street. For fixture with
symmetric light pattern, align fixture aesthetically.
Electrical service leads must be rated for 90º C
N
otee:
minimum. Loosen the strain relief screw, loop the
service lead wires under the nomex paper barrier,
through the strain relief, and tighten the strain relief
screw.
5.
Secure fixture to pole-top by tightening three set
screws. Recommended tightening torque; 120-140
inch pounds.
6.
Connect service lead wires to ballast terminal block
(black service lead wire to terminal #1 and white
service lead wire to terminal #2). Connect ground wire
to green ground wire or green ground screw in fixture
base.
7 .
Install lamp in lamp socket. Make sure lamp type and
rating agrees with fixture lamp label.
8.
Replace lens panels, close cover, and secure with cover
retaining screw or latches.
2
Photocontrol
For unit equipped with photocontrol receptacle
N
Receptacle has a built-in stop which permits 350° rotation.
Do not attempt to rotate beyond stop.
1.
2.
3.
Photocontrol must be rated to match fixture line voltage.
MAINTENANCE
The reflector's efficiency (if applicable) will be retained
only if cleaned at regular intervals (six months to one year
depending on local conditions). Clean with mild soap or
detergent and water, to liquid wax emulsion. The lens
panels should be cleaned along with the reflector using care
not to chip or scratch surfaces.
Do not use abrasives, solvents, strong alkalines, or acid
cleaners.
N
Installation Instructions – LXT/LXF Pole-Top Luminaire
IMI-253
ADH140714
www.cooperlighting.com
When specified, your LXT or LXF luminaire is
otee:
furnished with a rotatable photocontrol receptacle
that allows the photocontrol to be properly
positioned.
CAUTION
Loosen the cupola mounting screws. Rotate the cupola
until it can be removed.
Remove shorting cap (when furnished). Loosen the
photo control mounting ring screws and rotate the
receptacle until the indicator points north. Tighten
the photocontrol mounting ring screws. Install the
photocontrol and lock it in place by turning clockwise.
The photocontrol must contain a soft, resilient gasket
fastened to the bottom surface to assure a proper
weather seal between the control and the receptacle.
Replace cupola and make sure the photocontrol
window is centered in the cupola window. Tighten the
cupola mounting screws.
CAUTION
WARNING
All statements, technical information, and
otee:
recommendations contained herein are based on
information and tests we believe to be reliable. The
accuracy or completeness thereof is not guaranteed.
In accordance with Cooper Lighting Solutions "Terms
and Conditions of Sale, " and since conditions of
use are outside our control. the purchaser should
determine the suitability of the product for his
intended use and assumes all risk and liability
whatsoever in connection herewith.

Publicité

loading

Ce manuel est également adapté pour:

Streetworks lxf