Specifications - WIKA GLS-1000 Mode D'emploi

Contact à flotteur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Specifications

9. Specifications
Specifications
Output signal
Level
Temperature
Switching function
Switching current
Total current consumption Per switching output: max. 10 mA + switching current
Switch point accuracy
Power supply
Mounting position
Material
Wetted
Non-wetted
Permissible temperatures
Medium
Ambient
Storage
Electrical
connections
Circular connector
M12 x 1 (4-, 5- or 8-pin)
Cable outlet
Cable outlet
Cable outlet
1) Not with cable material: PVC, PUR
2) The stated ingress protection (per IEC/EN 60529) only applies when plugged in using mating connectors that
have the appropriate ingress protection.
WIKA operating instructions model GLS-1000
Up to 4 switch points, PNP or NPN
Pt100, 2-wire, class B per DIN EN 60751
Pt1000, 2-wire, class B per DIN EN 60751
Normally open or closed - see product label
Max. 200 mA
±1 mm
DC 5 ... 30 V
±30°
Process connection, guide tube: Stainless steel 316Ti
Float: See table page 18
Case: Stainless steel 316Ti
Electrical connection: See table below
-40 ... +80 °C [-40 ... +176 °F]
-40 ... +110 °C [-40 ... +230 °F]
-40 ... +80 °C [-40 ... +176 °F]
-30 ... +80 °C [-22 ... +176 °F]
Ingress protection
per IEC/EN 60529
IP65
IP67
IP67
IP67
1)
Material Cable
length
2)
-
TPU,
brass
PVC
PUR
other lengths
Silicone
on request
EN
2 m [6.5 ft]
5 m [16.4 ft]
17