Commissioning
2.1.

Binding

2.1.1.
Assignment to underfloor heating
controller
In order to assign a temperature zone to the HCW 82/
HCF 82, follow the instructions from the chapter entitled
"Start-up" in the "Underfloor heating controller
HCE 80/HCE 80R/ HCC 80/HCC 80R" installation
instructions.
2.1.2.

Assignment to evotouch

In order to assign a temperature zone to the HCW 82/
HCF 82, follow the instructions of the evotouch.
Press the Bind button to carry out binding.
2.1.3.

Failed binding

If the binding has failed:
Improve the data transfer (see below).
Repeat the binding procedure.
Improving the data transfer
When selecting the operating site of each device ensure
that the distance to radio devices such as radio
headphones, cordless phones, etc. according to the DECT
standard amounts to at least 1 m.
Do not install the devices over metallic wall connecting
sockets and at least 30 cm away from the cover of the heat
generator.
Correct the installation site of the room temperature sensor
if necessary.
8
2.2.

Installation

Remove the batteries.
Mark the drill holes according to the drilling template
(see Fig. 3).
Fig. 3: Drilling scheme (measurements in mm)
Drill the holes.
Screw on the room temperature
sensor.
Re-insert the batteries.
Place the housing cover in
position above and snap it down
(see Fig. 4).
Fig. 4:
Placing housing cover in
position