Mains
230V ~1/N/PE 50Hz
Output power
0,75 kW (1HP) S1
Reference current
Extension cord (H07RN-F): 3x1,5mm²
Installation fuse protection
4.2 Noise emission
Acoustic pressure level (EN 11202):
Idling
In operation
The specified values are emission
levels and are not necessarily to be
seen as safe operating levels.
As workplace conditions vary, this
information is intended to allow the
user to make a better estimation of the
hazards and risks involved only.
4.3 Content of delivery
Casting legs with levelling pads
300 mm tool rest
Tool rest extension
150mm face plate
Spur centre and tooling knockout bar
M33x3,5 spindle adapter
Live centre
Operating tools
Assembly kit
Operating manual
Spare parts list
5. Transport and start up
5.1 Transport and installation
The machine is designed to operate in
closed rooms and must be placed
stable on firm and levelled ground.
The machine can be bolted down if
required.
For packing reasons the machine is
not completely assembled
5.2 Assembly
If you notice transport damage while
unpacking, notify your supplier
immediately. Do not operate the
machine!
Dispose of the packing in an
environmentally friendly manner.
Clean all rust protected surfaces with
a mild solvent.
Attach the leg stand:
At this point the headstock, tailstock
and tool rest should be removed.
The machine bed is heavy! With the
help of a second person, carefully lift
3.7 A
bed up onto a workbench (Fig 1).
Attach the leg stand (B) with 8 hex
10A
socket cap screws and 8 lock washers
(D).
Thread adjustable feet (A) into stand
legs).
Adjust the feet so that the lathe rests
evenly on the floor, and tighten the
72,5 dB(A)
nuts (C).
78,4 dB(A)
Reinstall headstock, tailstock and tool
rest (Fig 2).
Stand shelf:
You can make an extra shelf that rests
between the legs if you wish
(see Fig 3).
Fig 1
Fig 2
Fig 3
5
5.3 Mains connection
Mains connection and any extension
cords used must comply with
applicable regulations.
The mains voltage must comply with
the information on the machine
licence plate.
The mains connection must have a
10 A surge-proof fuse.
Only use power cords marked
H07RN-F
Connections and repairs to the
electrical equipment may only be
carried out by qualified electricians.
5.4 Dust collection
Use a suitable dust collection and
filtration system to avoid a high dust
concentrations in the air.
5.5 Starting operation
You can start the machine with the
green on button. The red button on the
main switch stops the machine.
6. Machine operation
6.1 Correct operating position
Always support the tool on the tool
rest and guide with the palm of your
hand keeping your fingers closed.
(see Fig.4 and 5)
Fig 4
Fig 5