DC Application

The DC terminal is used for trickle charging 12 volt batteries or low
amperage drawing DC tools or appliances.. It provides 12V - 8.3A
(100W) of maximum power.

Connection of Cable

Connect positive terminal (red) on generator to positive (+) terminal on
battery.
Connect negative terminal (black) on generator to negative (-) terminal on
battery.
Safety Precautions While Charging a Battery
An explosive hydrogen gas is discharged through vent
holes in the battery during the charging process.
Do not allow spark or open flame around the generator
or battery during the charging process.
Electrolyte fluid can burn eyes and clothing. Be careful to avoid
contact. If injured, wash the affected area immediately with large quan-
tities of water and consult a doctor for treatment.
When charging a large capacity battery or totally discharged battery,
excessive current may force the DC breaker to turn off.
In such cases, use a battery charger to charge a large battery with AC
output.
Battery defects may cause the DC breaker to trip. Check the battery
before resetting the DC breaker.
OPERATION