Figure 4: Power connection
1. With a screwdriver, loosen the GND and ~AC24V/DC12V terminal
screws on the terminal block.
2. Connect a universal 12 VDC, 24 VAC power supply to the terminal
block.
Note: The terminal block is not polarity- sensitive. Either power lead
can be connected to either terminal connector. There is no need for an
isolated ground wire. The two power terminals can accept any polarity
and any combination of power that equals 12 VDC or 24 VDC.
3. Retighten the terminal screws until snug, ensuring that the power
leads are secure.
4. Supply power to the unit by plugging the power supply into a
proper source.
Note: The power LED illuminates to show that the camera is receiving
power. If it does not illuminate, check the terminal block connections
and the power source
Mount the camera
To mount the camera, attach the camera to the mounting surface using
the appropriate fasteners.
Connect the monitor
Program the cameras by attaching a standard video monitor to the
system.
To connect the monitor, do the following:
1. Plug the monitor output cable to the video monitor output
connector (see Figure 1 on page 3.)
2. Connect the BNC cable to the video monitor.
3. Press Enter (Figure 5 below) to display the Setup menu.