Figure 3: Attaching your lens
Video-type autoiris lens leads
A
B
C
D
Camera
Video-type autoiris lens leads: A. Red (9 VAC); B. NC (no connection); C. Black
(ground); D. White (video)
DC-type autoiris lens leads: E. Damping coil (+); F. Damping coil (-); G. Driving coil
(+); H. Driving coil (-)
1. If you are using a C-mount lens, screw on the provided C-mount
adapter.
2. Screw your customer-supplied lens onto the camera.
3. If you are using an autoiris lens, insert the autoiris lens plug into
the autoiris lens connector.

Connect power

Caution:
Use direct plug-in UL listed power supplies marked Class 2
or LPS (limited power source) of the required output rating as listed on
the unit.
Quick Start Guide
C-mount adapter
(for C-mount lenses only)
Autoiris, lens
connector
DC-type autoiris lens leads
Autoiris lens
plug
E
F
G
H
Lens (autoiris shown);
manual iris has no
cable
5 EN