Specifications - Panasonic MKG1500-DE Consignes D'installation

Unité de mesure électrique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5-1. Specifications

Item
Product Name
Model Number
Dimensions
Weight
Rated Voltage
Rated Current of
Current Transformer
Phase Systems
Power Cable
Measurement Points
Power Measurement Range
Power Measurement Accuracy
Total Cumulative Energy
Measurement Accuracy
Power Consumption
Installation Conditions
Temperature Range
Relative Humidity
Wireless Frequency
Transmission
Wireless Range
Receiver Category
(EN 300 220)
Overvoltage Category
(EN 61010)
Measurement Category
(EN 61010)
Compatible Standards
Environmental Standards
Specification
Power Measuring Unit
Unit
: MKG1500-DE
(Optional Parts)
CT Cable Set
: MKG1510-DE
CT
: MKG1520-DE
CT Cable
: MKG1530-DE
Extension cable (1 m) : MKG1540-DE
72 mm (W) × 90 mm (H) × 60 mm (D)
500 g
Single-phase 2-wire with earthed neutral : 220 - 240 VAC
3-phase 4-wire with earthed neutral: 220 - 240 VAC L-N, 380 - 415 VAC
L-L 50 Hz, Voltage variance ± 10 %
MKG1500-DE, MKG1510-DE, MKG1520-DE: 63 A
single-phase 2 wire / 3-phase 4 wire
 solid wire
2.5 mm
2
Main Supply / Solar PV / Storage Battery
Solar PV and battery require separately available CT and CT cable
Main: - 45 kW to + 45 kW (3-phase 4 wire: each 240 V)
* - 20 to + 20 W values read as 0 W
Solar PV: - 20 kW to + 20 kW (3-phase 4 wire: each 240 V)
* - 20 to + 20 W values read as 0 W
Storage Battery: - 20 kW to + 20 kW (3-phase 4 wire: each 240 V)
* - 20 to + 20 W values read as 0 W
± 3.0 % (cosφ=1: Rated from 5 % - 100 %)
± 2.0 % (cosφ=1: Rated 100 %)
(Conditions: Vin=230, V± 23 V, Ambient temp: 23 ℃ ± 5 ℃)
± 3.0 % (cosφ=1: Rated from 5 % - 100 %)
± 2.0 % (cosφ=1: Rated 100 %)
(Conditions: Vin=230, V± 23 V, Ambient temp: 23 ℃ ± 5 ℃)
2 W
Indoors, pollution degree 2, 2000m or less above sea level
residential switchboard, DIN rail ( 35 mm ) installed, for home use
- 10 to 50 ℃
85 % RH or lower (no condensation)
868 – 869 MHz
< 25 mW
One floor up or across
Up to 6 m between Power Measuring Unit and Home IoT Gateway
CAT Ⅱ
300 V / CAT Ⅲ
CAT Ⅲ
EMC : EN 61326-1 EN 301 489-1 EN 301 489-3 EN 62311
radio : EN 300 220-2
safety : EN 61010-1 EN 61010-2-030
RoHS REACH WEEE
19

Publicité

Table des Matières
loading

Table des Matières