Product Information; Installation Requirements - Wolf TM15TFS Guide D'installation

Masquer les pouces Voir aussi pour TM15TFS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
T EPPA N YAKI M OD U LE
Contents
Teppanyaki Module
2
Specifications
2
Installation
3
Troubleshooting
3
Features and specifications are subject to change at any
time without notice.
Important Note
To ensure this product is installed and operated as safely
and efficiently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE
highlights information that is especially
important.
CAUTION
indicates a situation where minor injury or product
damage may occur if instructions are not followed.
states a hazard that may cause serious injury or
WARNING
death if precautions are not followed.
IMPORTANT NOTE:
Save these instructions for the local
electrical inspector.
|
2
English

Product Information

Important product information including the model and
serial number are listed on the product rating plate. The
rating plate is located on the bottom of the unit. Refer to
the illustration below.
If service is necessary, contact Wolf factory certified service
with the model and serial number.
RATING
PLATE
Rating plate location.
S P E CIF IC ATIO N S

Installation Requirements

A minimum 22 mm is required from the bottom of the unit to
any material. Refer to the illustration on the following page
for additional minimum clearances.
WARNING
Failure to locate the unit without proper clearances
will result in a fire hazard.
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustration
on the following page. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Performance may be compromised if the electrical supply is
less than 240 volts.
When multiple cooktops or modules are installed side by
side, each unit must have its own separate recommended
electrical circuit.
EL EC T R I C A L R EQ U I R EMEN TS
Electrical Supply
220–240 V AC, 50/60 Hz
Max Connected Load
Cord
H05VV-F 1.5 mm² 3G
RATING
PLATE
Rating plate location.
2.8 kW