ENGLISH
MAINTENANCE
Switch the unit off and unplug the mains cable BEFORE servicing!
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
The unit and its installation conditions should be inspected and approved every 3 months by an authorized
expert!
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Power Input:
Maximum overall power:
Maximum power per phase:
Maximum power per output:
Protection class:
Max. Leakage current:
Automatic fuses / phase:
Diameter Power cord:
Diameter internal wiring:
Size:
Weight:
You can download the latest version of this user manual on our website: www.beglec.com
BRITEQ
®
DANGER TO LIFE:
IEC60309-standard, CEE-32A industrial plug
380V–400V / 50Hz, 3phase, 5wire (3P+N+E)
22.080Watt (3x 32A)
7.360Watt (32A)
3.680Watt (16A)
class I (only to be connected to class I outlets)
30mA
2x C16 (I
5x 6mm² (H07RN-F 5G6)
32A-wires: 10AWG (5,2mm²) – 16A-wires: 14AWG (2,1mm²)
see drawings
8.8 kg
Every information is subject to change without prior notice
=16A, instantaneous tripping current = 5x I
n
5/27
USER MANUAL
)
n
PD-32SH