Output 6: 230V/16A output socket connected to phase3 (L3) and protected by breaker 6 (C)
H. Ground Connection of the housing
I.
16-pin connector:
Pin 1: output connected to phase1 (L1) and protected by breaker 1 (C)
Pin 2: output connected to phase1 (L1) and protected by breaker 2 (C)
Pin 3: output connected to phase2 (L2) and protected by breaker 3 (C)
Pin 4: output connected to phase2 (L2) and protected by breaker 4 (C)
Pin 5: output connected to phase3 (L3) and protected by breaker 5 (C)
Pin 6: output connected to phase3 (L3) and protected by breaker 6 (C)
Pin 9, 10, 11, 12, 13, 14 = Neutral
Pin 7, 8, 15, 16 = not used
Side connector (cover) = Ground
J. Round 19-pin connector:
Pin 1: 230V/16A output connected to phase1 (L1) and protected by breaker 1 (C)
Pin 3: 230V/16A output connected to phase1 (L1) and protected by breaker 2 (C)
Pin 5: 230V/16A output connected to phase2 (L2) and protected by breaker 3 (C)
Pin 7: 230V/16A output connected to phase2 (L2) and protected by breaker 4 (C)
Pin 9: 230V/16A output connected to phase3 (L3) and protected by breaker 5 (C)
Pin 11: 230V/16A output connected to phase3 (L3) and protected by breaker 6 (C)
Pin 2, 4, 6, 8, 10, 12 = Neutral
Pin 13, 14, 15, 16, 17, 18 = Ground
Pin 19 = not used
INSTALLATION GUIDELINES
This unit may only be installed and electrically connected by an
Electrical installation should strictly follow all safety rules and
The complete installation should be approved by an authorized
expert before it will be taken into operation! Each change to an
Before connecting ANY equipment you should ALWAYS check the
voltage on the 3 phases: not following this rule can cost you a lot
MAINS INPUT: the unit should be connected to the mains via a 5pole 380-400V 32A CEE socket. The
maximum overall power is 22.080Watt which may never be exceeded!
OUTPUTS: each phase is connected via 2 separate 16A output sockets. The maximum power per phase
is 7.360Watt, each 16A output socket support maximum 3.680Watt which may never be exceeded!
BRITEQ
®
DANGER TO LIFE
authorized and qualified electrician!
technical norms for electrical installations in your country!
existing installation should be re-approved as well!
of money due to broken equipment. Briteq CANNOT be held
responsible in such cases!
/
EQUIPMENT:
4/27
USER MANUAL