TROUBLESHOOTING

Incorrect operations are often mistaken for trouble and malfunctions. If you think that there is something wrong with
this component, check the points below. Sometimes the trouble may lie in another component. Investigate the other
components and electrical appliances being used. If the trouble cannot be rectified even after exercising the checks
listed below, ask your dealer.
Symptom
Power does not turn
' The power plug is not connected to the
on.
power outlet.
' The power cord is not connected to the AC
IN connector of this unit.
No sound output.
' The speaker cable is disconnected or is not
connected correctly.
' The terminal or the speaker cable plug is
dirty.
' The power indicator flashes red.
' The BALANCED/UNBALANCED input
connector selector switch is set to
"UNBALANCED" even though a balanced
connection is being used.
' The BALANCED/UNBALANCED input
connector selector switch is set to
"BALANCED" even though an unbalanced
connection is being used.
' When the AUTO POWER DOWN switch is
set to "ON" power is suddenly disconnected
during playback.
Same sound is
' Though it is a stereo connection, BI-AMP
coming from both
Switch is set to "BI-AMP".
channels.
Possible cause
Remedy
' Firmly plug in the power cord to the power
outlet.
' Firmly plug in the power cord to the AC IN
connector.
' Firmly connect the speaker cable.
' Clean the terminal and plug.
' Refer to "Protection circuit" on page 14 and
eliminate the cause.
' Set the BALANCED/UNBALANCED input
connector selector switch to "BALANCED".
' Set the BALANCED/UNBALANCED
input connector selector switch to
"UNBALANCED".
' When the AUTO POWER DOWN function
is not necessary, set the switch to "OFF".
' Set the BI-AMP Switch to "Stereo".
15