6.5

BLOWER INSTALLATION

ENSURE THE UNIT IS COMPLETELY COOL BEFORE STARTING INSTALLATION
TO AVOID DANGER OF SUFFOCATION KEEP THE PACKAGING BAG AWAY FROM BABIES AND
CHILDREN.
DO NOT USE IN CRIBS, BED, CARRIAGES OR PLAY PENS. THIS BAG IS NOT A TOY.
Remove the screen by lifting it up and off of the appliance, refer to, "SAFETY SCREEN / DOOR
A.
REMOVAL AND INSTALLATION " section.
Unplug the control module transformer and lift the control module from the bottom of the appliance,
B.
move both the control module and transformer off to one side to ease installation of the blower.
Remove the two adhesive backing strips from the velcro strips located on the fan mounting bracket of
C.
the blower.
Attach the two 1/4" connectors (black and white) from the wire harness to the thermodisc.
D.
Attach the two 1/4" connectors (black and red) from the wire harness to the blower.
E.
Pivot the blower into the bottom of the appliance, center it on the left side wall of the outer shell. Press
F.
the blower fi rmly against the outer shell so the adhesive sticks to the appliance.
G.
NOTE: ENSURE ALL WIRES REMAIN CLEAR OF THE BLOWER.
Place the control module back into it's original position. Ensure the transformer is plugged into the
H.
rear outlet of the electrical box, refer to Figure 1.
Remove the adhesive backing strip from the velcro strip located on the variable speed switch (VSS).
I.
Place the VSS fi rmly into position on the front left corner of the base of the outer shell, refer to Figure
1. Plug the connector from the VSS to the matching connection on the wire harness.
Position the magnetic thermal disc bracket on the fi rebox base approximately 4" (101.6mm) from the
J.
front of the appliance, refer to Figure 2. Ensure the wire harness is properly attached.
Plug the power cord from the blower into the electrical box, refer to Figure 1.
K.
NOTE: The blower is thermally activated, so when it is turned on, it will automatically start
approximately 15 minutes after lighting the appliance and will run for approximately 30 minutes after
the appliance has been turned off.
FIGURE 1
ELECTRICAL
BOX
VARIABLE
BLOWER
SPEED
POWER
SWITCH (VSS)
CORD
WARNING
!
KNOT BEFORE THROWING AWAY.
FIGURE 2
CONTROL
MODULE
ELECTRICAL
BOX
VARIABLE
BLOWER
SPEED
POWER
SWITCH (VSS)
CORD
W415-1397 / 09.30.14