Requirements of Installation Tools
Type
Tools
Claw hammer,
pliers
Phillips-head
screwdriver,
straight screw-
driver, spanner
Power supply
Common
cables, network
Tools
cables, optical
fibers and distri-
bution cables
Ruler, long
tapeline, marker
pen
Bolts, diagonal
pliers, straps
Anti-static tool
Special-
purpose
Wire stripper,
Tools
crimping pliers
Multimeter
Meter
500V megohm-
meter
Table 3. Required Tools

Installation Site Requirements

The DES-7200 must be used indoors. To
ensure the normal operation and prolonged
useful file of the equipment, the installation site
must meet the following requirements.
Requirements for Rack Mounting
If you plan to mount the DES-7200 in a frame,
please observe the following guidelines:
-
Install the switch in an open cabinet if
possible. If you install the switch inside
a closed cabinet, please ensure that the
cabinet has a good ventilation and heat
dissipation system.
-
Ensure that the cabinet is durable enough
to bear the weight of the DES-7200 and its
installation accessories.
Remarks
Unpack wooden
case and transpor-
tation case.
Disassemble
chassis, power
supply, fan and
modules.
Connect the inter-
faces.
Measure the instal-
lation position.
Mount the chassis.
Prevent static
electricity.
Create network
cables and
grounding cables.
Test power supply
and DC resistance.
Test the insulation
resistance and
grounding resis-
tance.
-
Ensure that the dimensions of the cabinet
provide enough space for the installation of
the front, rear, left and right panels of the
DES-7200 for the sake of heat dissipation.
-
The frame should be properly grounded.
Ventilation Requirements
Following figure shows the ventilation
requirements of the DES-7200. You must
reserve sufficient spacing near the vents to
ensure proper ventilation. After the cables
have been connected, they should be arranged
into bundles or placed on the cabling rack, to
prevent the obstruction of air inlets and vents.
Figure 3. Ventilation of the DES-7200
Mounting the DES-7200 into the Cabinet
1.
With a person on each side of the
DES-7200, lift the chassis while keeping
it level. Slowly move it to the front of the
frame.
2.
Keeping the DES-7200 level, lift it to a
position slightly higher than the tray or the
slide rail of the cabinet. Set the chassis onto
the tray or the slide rail, and push it into the
cabinet.
3.
Fasten the DES-7200 to the cabinet with
screws. Fastening notches are on both the
left and right side of the front panel on the
equipment frame. Use screws to fasten
them to the bracket of the cabinet. Once
fastened, the equipment should be stable
and immobile.
6/10 Slot Chassis-Based Switch  5