Observe the maximum supply pressure of the com-
pressed air supply. Refer to Chapter "10) Technical data"
on page 11.

Remove the used cartridges

Refer to figures {L} and {M} on page III:
1. Release the trigger (21) and press the red button (19)
(a) until the plungers have moved to the rear stop.
No. Fault
Plunger discs cannot en-
1
ter the cartridge
The cartridge cannot be
2
removed from the dis-
penser
3
Dispensing is interrupted
Material discharge is in-
4
terrupted
Spraying procedure is in-
5
terrupted
Instruction handbook
Version 1.0 · 23.12.17
2. Release the atomizing air line from the spraying
3. Push out the cartridges from below and remove
Cause
• Use of cartridges that are not sup-
plied by Henkel
• Cartridge not fully inserted in car-
tridge sleeve
• Incorrect plunger disc
The plunger discs are still in position
inside the cartridge
Compressed-air supply has been in-
terrupted
Material has hardened in the mixer
Atomizing air supply has been inter-
rupted
10 of 12
head (b).
upwards (c).
Dispose of the cartridge, mixer and atomizing
air line in accordance with the manufacturer's
instructions.
Remedy
• Check that there is no foreign mat-
ter in the cartridge sleeve.
• Push the cartridge fully down into
the cartridge sleeve.
• Press the red button (19) to fully re-
tract the plunger discs to the back
end-stop (see "Remove the used
cartridges", page 10)
• Check the compressed-air line
• Replace the mixer (see "Fix the mi-
xer onto the cartridge", page 9)
• Check the atomizing air line and the
quick connectors (see "Fix the mixer
onto the cartridge", page 9)
EN