CoolPower MPS50
5
Technical description
The mains rectifier can operate all coolers and refrigerators with BDF-50
compressors at 110 – 240 Vw. With a 110 – 240 Vw mains connection, the
rectifier automatically switches from battery to mains operation.
When disconnected from the 110 – 240 Vw mains supply, the rectifier auto-
matically switches back to battery operation. Mains operation via the rectifier
always takes priority over battery operation.
5.1
Control elements
Item
in fig. 1, page 3
1
2
3
4
5
6
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
The place of installation must be well-ventilated. A ventilation system
which is at least equivalent to the air openings in the device must be
present for installations in closed housings.
The air intake on the underside or the air outlet on the back of the device
must remain clear.
The installation surface must be level and sufficiently sturdy.
➤ Secure the mains rectifier with screws through the fastening holes at the
front and the back of the device (fig. 1 3, page 3).
EN
Explanation
12/24 V socket
Glass fuse (250 V, 12 A, slow-blow)
Fastening holes
Compressor output terminals
Battery input terminals
Mains cable
Technical description
21