Technical description

The mains rectifier can operate all coolers and refrigerators with BDF-50
compressors at 110 – 240 Vw. With a 110 – 240 Vw mains connection, the
rectifier automatically switches from battery to mains operation.
When disconnected from the 110 – 240 Vw mains supply, the rectifier auto-
matically switches back to battery operation. Mains operation via the rectifier
always takes priority over battery operation.
5.1

Control elements

Item
in fig. 1, page 3
1
2
3
4
5
6
6

Mounting the mains rectifier

If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
 Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
 The place of installation must be well-ventilated. A ventilation system
which is at least equivalent to the air openings in the device must be
present for installations in closed housings.
 The air intake on the underside or the air outlet on the back of the device
must remain clear.
 The installation surface must be level and sufficiently sturdy.
➤ Secure the mains rectifier with screws through the fastening holes at the
front and the back of the device (fig. 1 3, page 3).
EN
Explanation
12/24 V socket
Glass fuse (250 V, 12 A, slow-blow)
Fastening holes
Compressor output terminals
Battery input terminals
Mains cable
Technical description
21