Emergency escape
The operator can be fitted with different emergency escape units to ensure a safe evacuation of the
building.
Break-out unit PSB
The door leaves and the side screens are swung outwards when a defined pressure is applied.
The break-out function can also be used to create a wider opening. From the fully swung out position,
the door leaves can be manually slid sideways, offering the possibility to transport wide objects
through the opening, or to make a shop entrance more inviting during good weather.
Mechanical emergency unit (MEU)
An elastic cord is used to open the door in the event of power failure. Until the power is restored,
the door remains open. The operator will then resume the function set by the mode selector. The
emergency unit is monitored by the operator control unit. A monitoring error means that the door
opens and remains open until the error is cleared.
For further information,
Electrical emergency unit
The door is opened by means of a rechargeable battery unit in the event of a power failure. The door
remains in this position until the power is restored. The operator will then resume the function set
by the mode selector. The battery unit is monitored by the operator control unit. A monitoring error
is indicated by flashing red LED on the operation mode selector (OMS) and the door remains in open
position until the error is cleared.
For further information,
The electrical emergency function can also be used to close the door in the event of power failure.
The fire authorities make this a requirement to stop fire or smoke from spreading throughout the
building.