Operation mode selectors
The door functions are set with different operation mode selectors.
The operation mode selector is available with 5 positions (plus RESET).
The key on the PSK-6U, OMS Standard and OMS BLE mode selectors must always be removed on
emergency escape doors after changing settings.
OMS Standard and OMS BLE - Modes
OPEN, AUTO PARTIAL, AUTO, EXIT and OFF modes can be obtained.
Symbol
Note! If monitored emergency unit is a demand, a test of the emergency unit is performed when
the operation mode selector is set from OFF or OPEN to any other operation mode.
1009875-multi-1-13.0
Text
Mode
The door is permanently open. The door can be moved by hand
e.g. for window cleaning. All activation units except for the
OPEN
emergency push button (if fitted) are disconnected.
Two-way traffic, AUTO PARTIAL is obtained. The door can be
AUTOPAR-
opened partially with the inner and outer activation units and
TIAL
with a key switch (if fitted). With an emergency push-button (if
fitted) the door opens fully.
Two-way traffic, normal operation of the door. The door can be
opened fully with the inner and outer activation units and with a
AUTO
key switch/emergency push-button (if fitted).
One-way traffic passage from inside only. The door is normally
EXIT (ONE
locked if an electromechanical locking device has been fitted. The
WAY)
door can only be opened with the inner activation unit or with a
key switch/emergency push-button (if fitted).
The door is closed and locked (if an electromechanical lock is fit-
ted). In an escape route the OFF mode may only be set after it is
certain that all people have left the building.
The door cannot be opened with inner and outer activation units.
The door can be opened partially with a key switch (if fitted). The
door can be opened fully with an emergency push button (if fit-
ted).
When the mode selector is in OFF mode the OFF button can give
OFF/CLOSED
a key impulse. The key impulse will open the door to partial open
position. There are 3 different ways how the OFF button works,
depending on the configuration.
1
It is not possible to give a key impulse.
2
It is always possible to give a key impulse by pressing the OFF
button for 2 seconds.
3
The mode selector must first be unlocked then it is possible
to give a key impulse by pressing the OFF button for 2 second.
By briefly pushing the button (placed in the hole accessible from
the underside of the unit) with a narrow object, the door operator
will make a RESET function with system test. The door will return
to closed position (if not in operating mode selection OPEN or if
RESET
an error is present) and is then ready for normal operation.
If the operator is equipped with emergency unit for escape, the
operator will test the emergency unit by opening with battery
after the doors have closed with low speed (if operation mode
selection is not OPEN or OFF).
Issue 2022-03-04
EI