When making these connections contemplate means for disconnecting from the power grid with a
minimum contact separation of at least 3 mm (0,12") for all poles. These disconnection means must be
incorporated into the fixed installation.
The hair dryer must be installed against a solid surface only (wall, partition, or similar).
Carefully place the casing on the base of the device. To do so place it over the base with a slight incline
from top to bottom, in such a way that the tab in the casing correctly inserts into the corresponding slot in
the base (Figures 8 and nº 9).
Place the screws for fixing the casing to the base, fixing them tightly using the special spanner provided
(Figure 10).
Fig. 9
During the installation procedure, the protection areas must be considered in
accordance with VDE0100.
The hair dryer appliance must be installed on a closed surface, wall, partition or similar.
Hair dryer must be installed far from a person who is taking a showr or a bath.