ATTENTION: WHEN THE CASING IS DISMANTLED ACTIVE PARTS OF THE DEVICE BECOME
ACCESSIBLE
Assembly
Connection to the power grid will be preferably through the rear plug.
In order to assemble the hair dryer complete the following steps:
Make four drill holes with an 8 mm (0,31") diameter in the wall, using the provided template
(Figure 4).
Clean the dust away from the holes and insert the wall plugs.
Pass the electrical cables from the power grid through the hole with the 22 mm (0,87")
diameter which is situated above the device's terminal strip (Figure 5).
Firmly screw the base of the device to the wall (Figure 6), ensuring that the 4 silent-blocks
are correctly placed between the base and the wall.
Connect the electrical cables to the hair dryer's terminal strip. Connect the cables
corresponding to the two phases (N and L) and to earth in the corresponding sockets of the
terminal strip, as indicated by the engraved letters (Figure 7).
Fig. 6
Fig. 4
Fig. 7
www.mediclinics.com
Fig. 5
Fig. 8