OUTDOOR USE ONLY
DOM ETRE INSTALLE A L'EXTERIEUR
Kichler Design Pro LED Under Rail Fixture Installation Instructions
READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION
KEEP THESE INSTRUCTIONS
This fixture is intended for installation in accordance with the National Electric Code (NEC) and Local code specifications.
Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool, spa, or fountain.
2) This fixture is to be used only with a power unit (transformer) rated a maximum of 300 W (25 AMPS) 15 volts.
3) The 18AWG fixture wire is not intended for direct burial.
4) Direct burial rated wire is to be buried a minimum of 6" (152mm) beneath the surface of the ground. NOTE: If additional Direct Burial
wire is needed, contact your local Kichler® landscape distributor.
8 GA wire can be purchased in length of 250' (76 M), 15503-BK.
10 GA wire can be purchased in length of 250' (76 M), 15504-BK.
12 GA wire can be purchased in lengths of 100' (30 M), 15501-BK; 250' (76 M), 15502-BK; 500' (152M), 15505-BK; and
1000' (304 M), 15506-BK.
5) DO NOT INSTALL under stairs where the tread overhangs the riser less than ¾" [19 mm]
6) Wiring connections must be made with approved/listed wire connection device(s) suitable for the application. Do not exceed manufacturers'
wiring combination specifications for size and quantity of conductors.
INSTALLATION OF 15735, 15736, or 15755, IN RAILING, DECK OVER-HANG OR STAIR
(SEE FIG. A)
1) Turn off power.
2) Determine the desired location for the fixture. If using 15717, 15718 or 15719 accessory, please refer to accessory instruction sheet.
3) If desired, a wireway hole can be drilled through the decking fascia or other surface adjacent to the mounting surface.
a. Hold the fixture in the desired mounting location. Mark the location where the wire exits the fixture.
b. Drill hole though surface. (suggested ¼" [6.5 mm] hole)
c. Thread the wire through the hole.
4) Install fixture using #8 wood screws (provided). If screws are difficult to install, mark holes and drill 1/8" pilot holes.
NOTE: DO NOT OVER TIGHTEN SCREWS.
5) Connect fixture wires to main low voltage supply cable using the connector(s) provided.
FIG. A
Turn off power.
The full length of the 18 GA fixture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are
met:
• Wiring is to be protected by routing close to the fixture or accessory or secured to a building structure such as house or deck.
• 18 GA fixture wiring is to be cut off so that it is attached to the connector within 6 inches of the fixture or building structure.
• If it is necessary to make the connections underground, then no more than 6 inches of the 18 GA fixture wire is to be buried.
The Quic Disc
supply wire.
Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc
marked 12 GA on Quic Disc
Place the 18 gauge fixture wire across the area marked 18 GA on the Quic Disc
Quic Disc
screw is tightened all the way down.
The copper contacts will automatically pierce the wires' insulation. Excess 18 GA fixture wire that sticks out the end of the Quic Disc
Make no other wiring connections to the 18 GA fixture wire.
WE WARRANT THE LANDSCAPE PRODUCTS FEATURED IN OUR LANDSCAPE LIGHTING CATALOG (WITH THE EXCEPTION OF LIGHT BULBS) FOR FIVE YEARS AGAINST
DEFECTS IN MATERIALS AND WORKMANSHIP IF IT WAS PROPERLY INSTALLED AND FAILED UNDER NORMAL OPERATING CONDITIONS, PROVIDED IT IS RETURNED TO
THE POINT OF PURCHASE, WHERE IT WILL BE REPAIRED OR, AS IT MAY BE DETERMINED, TO REPLACE THE LANDSCAPE PRODUCT OR PARTS USED ON THAT PRODUCT.
Date Issued: 6/25/10
P/N: 15735AZT/BBR/CO, 15736AZT/BBR/CO, 15755AZT/BBR/CO
Dev. No: CP300349AZT/BBR/CO, CP300350AZT/BBR/CO, CP300351AZT/BBR/CO
QUIC DISC
connector is designed to install one fixture and accommodates one 18 GA fixture wire and one 10 GA or one 12 GA
.
to the base with supplied screw, making sure that the wires remain flat in the bottom portion of the Quic Disc
For Assembling and Installing Fixtures in Canada
Pour L'assemblage et L'installation Au Canada
WIRING INSTRUCTIONS
or place the 12 gauge supply wire across the area
WARRANTY
INSTRUCTIONS
. After the wires are in place, connecta the top of the
, and the
is to be cut off.
IS-15735-CB

Publicité

loading

Sommaire des Matières pour Kichler Design Pro 15735AZT

  • Page 1 DOM ETRE INSTALLE A L’EXTERIEUR For Assembling and Installing Fixtures in Canada Pour L’assemblage et L’installation Au Canada Kichler Design Pro LED Under Rail Fixture Installation Instructions P/N: 15735AZT/BBR/CO, 15736AZT/BBR/CO, 15755AZT/BBR/CO Dev. No: CP300349AZT/BBR/CO, CP300350AZT/BBR/CO, CP300351AZT/BBR/CO READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION KEEP THESE INSTRUCTIONS This fixture is intended for installation in accordance with the National Electric Code (NEC) and Local code specifications.
  • Page 2 4) Le câble à tension nominale à enfouir doit être enfoui à une profondeur minimale de 6 po (152 mm) sous la surface du sol. NOTE : Si un câble à enfouir supplémentaire est requis, veuillez prendre contact avec votre distributeur d’aménagement paysager Kichler® le plus près de chez vous.

Ce manuel est également adapté pour:

Design pro 15736aztDesign pro 15755aztDesign pro cp300349aztDesign pro cp300350aztDesign pro cp300351aztDesign pro 15735bbr ... Afficher tout