Calibration box

EU Directive 2004/108/EG (EMC Directive) and EMC law
Noise immunity: EN 61326-1
Emission: EN 61326-1, class A
Intended use
The BTL calibration box is used to set the null and end
points of the BTL transducer.
Opening the calibration box or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
general safety notes
Installation and startup of the BTL may only be
performed by trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
Technical data
Supply voltage range
Current draw (without BTL)
Voltage measuring channel characteristics
Measuring range
Resolution
Accuracy
Current measuring channel characteristics
Measuring range
Resolution
Accuracy
Degree of protection per IEC 60529
Operating temperature range
Wiring safety
Overvoltage protection
Inverse-polarity protection
Startup
DAnger
Uncontrolled system movement
The system must be taken out of operation before
f
making adjustments.
f
Transducers may only be connected to the
calibration box for setting purposes.
The calibration box must be removed after setting is
f
complete.
1
english
english
Construction and function
The BTL calibration box facilitates setting the null and end
points of BTL transducers equipped with an analog
interface. One major advantage is that the measured
output can be verified in real time using the LCD display on
the calibration box.
10 to 30 V
Max. 50 mA
–11 to +11 V
10 bit
±30 mV
0 to 23 mA
The BTL calibration box is suitable for BTL transducers
10 bit
with high-active programming inputs.
±50 µA
Examples:
IP40
0 to +50°C
Yes
36 V
–36 V
Downloading further instructions
A complete user's guide for the respective transducer can
be downloaded from the Internet at www.balluff.com/
downloads-btl6 or www.balluff.com/downloads-btl7
or requested via e-mail from service@balluff.de.
4
1
2
1
Button 1 (
programming input La)
2
Button 2 (
programming input Lb)
3
Selects the BTL output to be measured
4
8-pin socket
5
6-pin socket
BTL6-A/C/E/G500-M_ _ _ _-PF-S115
BTL7-A/C/E/G-M_ _ _ _-_-S32/S115/cable
(not for BTL7 USB-configurable)
The device must have high-active programming
inputs.
The calibration procedure is described in the
transducer user's guide.