BTL7-A-CB02-...
Calibration box
Connecting the calibration box
Connecting the calibration box with an S32/S115 connector:
1)
Connecting the calibration box with a cable connection:
1)
1) Construction example
2) Note the supply voltage range of the BTL
Operating the calibration box
Selecting the output display:
Step 4
Make sure to set the correct function according
to the connector/cable variant used.
Transducer outputs: display, pin assignment, measuring range
function 3)
Step 1 4)
U1
Step 2
U2
Step 3
I S32/KA
Step 4
I S115
3) Is shown on the display
4) After the system is turned on
www.balluff.com
S32/S115
8-pin
YE
YE
GY
GY
Cable
PK
PK
RD
RD
GN
GN
8-pin
BU
BU
BN
BN
WH
WH
8-port luster terminal
Step 1
Step 3
Designation
Voltage output 1
Voltage output 2
Current output S32/cable
Current output S115
Calibration box
BN
BU
6-pin
Calibration box
BN
BU
6-pin
Step 2
BTL version
S32
S115
Cable version
Pin
Pin
Wire color
5
5
Green (GN)
3
3
Pink (PK)
1
—
Yellow (YE)
—
5
—
Supply
voltage
10 to 30 V 2)
GND
2-port luster
terminal
Supply
voltage
10 to 30 V 2)
GND
2-port luster
terminal
Measuring
range
–11 to +11 V
–11 to +11 V
0 to 23 mA
0 to 23 mA
english
english
2