8
Automatic re-closing programming.
1) Close the gate (led f.ch turns off) and press once button SET (led DL3 starts flashing slowly).
2) Press once the button BREAK; led SPIA starts flashing indicating that the control panel is about to count the re-closing timing.
3) To stop the count, press once again the button BREAK (led Spia and led DL3 will turn off).
Maximum re-closing time programmable is 120 seconds.
If you w ant to disable this function or erase it:
Press once SET and then press BREAK twice (2 times) but within 2 seconds.
9
Pedestrian opening programming.
In the control panel exist already a standard pedestrian opening programmed of about 1 mt. You should have just to program a
remote control button on the pedestrian input (see chapter 4), nothing else.
If you want to get a different space for the pedestrian opening then read the followings instruction:
1) Press twice SET (led DL3 flashes quickly).
2) Then press once WORK; the gate starts opening.
3) When it has reached the desired position, press for a 2nd time WORK, the gate stops and led DL3 turns off.
The control panel has memorised the position and automatically re-closes the gate till it reaches the limit switch in closing position.
The slowing down space for the pedestrian opening will be the same as programmed for the normal opening on Start function.
10
Programmable functions by dip swit ch SW1 and SW2 .
SW1
1
If set in ON, the control panel ignores the Start function if the gate is already opening
2
If set in ON, after the photocells have been disengaged, the automatic re-closing will be done after 3 sec.
3
If set in ON, when photocells are engaged the gate stops its movement both in opening and closing and it doesn't move
until the photocells are disengaged, then the gate re-start opening. If set in OFF when photoc ells are engaged the gate
reverses the stroke but only during the closing.
4
If set in ON warning light flashes for 3 seconds before any gate movement
SW2
1
If set in ON the control panel works without encoder (anti-crashing function not working)
2
It selects the type of the safety edge. With dip set in OFF safety edge with input normally closed (NC), with dip set in ON
safety edge with 8,2K ohm resistance if not engaged, or with 0ohm r esistance if engaged. With infinite resistance if the
safety edge is broken.
11
Trimmer description.
SENS
It adjusts the sensitivity of the door (anti -crashing function) when it moves.
If turned unticlockwise (-) sensitivity very high. If turned clockwise (+) sensitivity very low.
This parameter gives the security level of the installation.
POWER
Force adjusting. Anticlockwise (-), minimum force; clockwise (+) max force.
PW.RALL
Force adjusting during slowing down space. Anticlockwise (-), minimum force; clockwise (+) max force.
DESCRIPTION
DESCRIPTION