20
9.2.2
TO SET REFRIGERATION PARAMETERS
Command 41 Internal temperature:
This command sets the internal operating temperature of the machine. The preset value is +3°C and can be
varied between +3-25°C. To set the temperature at +5°C, proceed as follows:
1. Go into programming mode to display .....................................................................................Command 00
2. Key in 41 and press B to display the present value of the parameter ..................................................... NN
3. Key in 5 and press B.
Command 43 Sets temperature to end defrost cycle:
This command sets the temperature at the end of the defrost cycle, i.e. the temperature measured by the
probe installed on the evaporator. When the set temperature is reached the defrost cycle is terminated. The
preset value is +10°C and can be varied between +8°C and +15°C.
E
Command 44 Sets defrost cycle frequency:
N
This command sets the interval in hours between the defrost cycles, i.e. the interval between one defrost
G
cycle and the next. The preset value is 120 and can be varied between 30 and 180 minutes.
L
I
Command 45 Sets alarm off time:
S
This command sets the fridge safety feature activation delay time. This delay prevents machine function
H
from being blocked following an operation involving opening of the door and consequently an increase in the
internal temperature. Delay in the intervention of the safety feature allows the machine to achieve the correct
working temperature. The value of this command is preset at 60 minutes and can be varied between 30 -
180 minutes.
Command 46 Sets safety control temperature:
This command sets the safety feature intervention temperature, i.e. the temperature above which the
selections are blocked while relevant warning message is shown on the display. This control is inhibited
when the machine is switched on and after the door is closed for the time set at command 45. The preset
value is +8°C, but can be varied between +8°C and +35°C. When the safety feature intervenes, the
selections remain out of order until the door is next opened.
Before resetting the "REFRIGERATION SAFETY DEVICE" alarm, ensure that the products inside the
vending machine are suitable for consumption.
Command 47 Sets the maximum switching off time:
This is the maximum time, expressed in minutes, in which the machine can remain switched off without the
fridge safety feature intervening when the machine is switched back on. This can be used to prevent the sale
of products which have altered as a result of a prolonged line voltage cut-out. The parameter can vary from
30 to 999 min.and is preset at 999.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
During installation time we suggest you to set the value at 180 minutes.
HEALTH CONTROL
The machine is allowed between 30 and 60 minutes to pull down to its correct working
temperature after the main cabinet door has been opened, the sale will be inhibited if
the temperature, which has been pre-set at command 46 (generally 8°) has been
execeeded or if there has been a power cut. The display shows the message: Health
control (Fridge safety has intervened). To restore the frige safety: open the machine,
insert the feeding key for some seconds (micro 230V) leaving the door micro switch
open, remove the key and close the door.
The products must be introduced at the correct temperature for preservation as
specified by the regulations in force. The non-observance of this regulation could
activate the "refrigeration unit safety device".
Spirali HDR Panzer - Issue 00