TECHNICAL DATA

Usable Column length ..........................................................
Bevel.....................................................................................
Drilling capacity max.............................................................
Length/Width/Height .............................................................
Weight according EPTA-Procedure 01/2014 ........................
WARNING Read all safety warnings, instructions,
illustrations and specifi cations provided with this
power tool. Failure to follow all instructions listed below
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
DIAMOND DRILL SAFETY WARNINGS
When performing drilling that requires the use of water,
route the water away from the operator's work area or
use a liquid collection device. Such precautionary
measures keep the operator's work dry and reduce the risk
of electrical shock.
Operate power tool by insulated grasping surfaces,
when performing an operation where the cutting
accessory may contact hidden wiring or its own cord.
Cutting accessory contacting a "live" wire may make
exposed metal parts of the power tool "live" and could give
the operator an electric shock.
Wear hearing protection when diamond drilling.
Exposure to noise can cause hearing loss.
When the bit is jammed, stop the applying downward
pressure and turn off the tool. Investigate and take
corrective actions to eliminate the cause of the bit jamming.
When restarting a diamond drill in the workpiece check
that the bit rotates freely before starting. If the bit is
jammed, it may not start, may overload the tool, or may
cause the diamond drill to release from the workpiece.
When securing the drill stand with anchors and
fasteners to the workpiece, ensure that the anchoring
used is capable of holding and restraining the machine
during use. If the workpiece is weak or porous, the anchor
may pull out causing the drill stand to release from the
workpiece.
When securing the drill stand with a vacuum pad to the
workpiece, install the pad on a smooth, clean,
non-porous surface. Do not secure to laminated
surfaces such as tiles and composite coating. If the
workpiece is not smooth, fl at or well affi xed, the pad may
pull away from the workpiece
Ensure there is suffi cient vaccum before and during
drilling. If the vacuum is insuffi cient, the pad may release
from the workpiece.
Never perform drilling with the machine secured by the
vacuum pad only, except when drilling downwards. If
the vaccum is lost, the pad will release from the workpiece.
When drilling through walls or ceilings, ensure to
protect persons and the work area on the other side.
The bit may extend through the hole or the core may fall
out on the other side.
Do not use this tool for overhead drilling with water
supply. Water entering the power tool will increase the risk
of electric shock.
ADDITIONAL SAFETY AND WORKING INSTRUCTIONS
When coring through fl oors, cores generally drop from the
bit. Provide proper protection for people and property below
the coring area.
Use protective equipment. Always wear safety glasses
when working with the machine. The use of protective
clothing is recommended, such as dust mask, protective
gloves, sturdy non-slip footwear, helmet and ear defenders.
26
ENGLISH
470 408 - MXFDR255TV.indd 26
470 408 - MXFDR255TV.indd 26
CORING MOTOR
..................................... 617 mm
.................................... 0-45 °
..................................... 250 mm
....................... 465/275/975 mm
.................................... 13,2 kg
The dust produced when using this tool may be harmful to
health. Do not inhale the dust. Wear a suitable dust
protection mask.
Do not machine any materials that present a danger to
health (e.g. asbestos).
Switch the device off immediately if the insertion tool stalls!
Do not switch the device on again while the insertion tool is
stalled, as doing so could trigger a sudden recoil with a
high reactive force. Determine why the insertion tool stalled
and rectify this, paying heed to the safety instructions.
The possible causes may be:
• it is tilted in the workpiece to be machined
• it has pierced through the material to be machined
• the power tool is overloaded
Do not reach into the machine while it is running.
The insertion tool may become hot during use.
• when changing tools
• when setting the device down
Chips and splinters must not be removed while the
machine is running.
When working in walls ceiling, or fl oor, take care to avoid
electric cables and gas or waterpipes.
SPECIFIED CONDITIONS OF USE
The diamond drill stand is intended for use with Milwaukee
diamond drills. It must be attached to the fl oor or wall by
means of vacuum or anchors.
Do not use this product in any other way as stated for
normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product
described under "Technical Data" fulfi lls all the relevant
provisions of the directives 2006/42/EC and the following
harmonized standards have been used:
EN 62841-1:2015
EN 62841-3-6:2015
Winnenden, 2020-01-03
Alexander Krug
Managing Director
Authorized to compile the technical fi le
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
OPERATION WITH A VACUUM PUMP.
The substrate under the drill stand has to be clean,
fi rm, smooth, dry, and not have any holes in it. The use
on plaster or masonry is not possible.
In case of malfunction, stop the work immediately and
remove the drill stand completely.
In case of a malfunction, the vacuum only remains for
a short period of time. The retention force depends on
the substrate and seal.
Additionally secure the drill stand against falling, e.g.
with rope or suitable supports.