Electrical Connections - Allmatic KALOS XL Mode D'emploi

Masquer les pouces Voir aussi pour KALOS XL:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
- ATTENTION - FOR THE SAFETY OF THE PEOPLE IT IS IMPORTANT
TO FOLLOW ALL THE INSTRUCTIONS.
1° - This handbook is exclusively addressed to the specialized personnel
who knows the constructive criteria and the protection devices
against the accidents for motorized gates, doors and main doors
(follow the standards and the laws in force).
2° - The installer will have to issue to the final user a handbook in
accordance with the EN 12635.
3° - Before proceeding with the installation, the installer must forecast
the risks analysis of the final automatized closing and the safety of
the identified dangerous points (following the standards EN 12453/
EN 12445).
4° - The wiring harness of the different electric components external to
the operator (for example photoelectric cells, flashlights etc.) must be
carried out according to the EN 60204-1 and the modifications to it
done in the point 5.2.2 of the EN 12453.
5° - The possible assembly of a keyboard for the manual control of the
movement must be done by positioning the keyboard so that the
person operating it does not find himself in a dangerous position;
moreover, the risk of accidental activation of the buttons must be
reduced.
6° - Keep the automatism controls (push-button panel, remote control
etc.) out of the children way. The controls must be placed at a
minimum height of 1,5mt from the ground and outside the range of
the mobile parts.
7° - Before carrying out any installation, regulation or maintenance
operation of the system, take off the voltage by operating on the
special magnetothermic switch connected upstream it.
THE ALLMATIC COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for
possible damages caused by the non observance during the installation of
the safety standards and of the laws in force at present.
KEEP THESE INSTRUCTIONS WITH CARE
1° - Install a thermal magnetic switch (omnipolar, with a minimum
contact opening of 3 mm) before the control board, in case this
is not provided with it. The switch shall be guaranteed by a mark
of compliance with international standards. Such a device must
be protected against accidental closing (e.g. Installing it inside the
control panel key locked container).
2° - As far as the cable section and the cable kind are concerned,
ALLMATIC suggests to use an H05RN-F cable, with a minimum
section of 1,5mm 2 , and to follow, In any case, the IEC 364 standard
and Installation regulations In force In your Country.
3° - Positioning of an eventual pair of photocells: The beam of the
photocells must be at an height not above the 70 cm from the
ground, and, should not be more than 20 cm away from the axis of
operation of the gate (Sliding track for sliding gate or door, and the
hinges for the swing gate). In accordance with the point 7.2.1 of EN
12445 their correct functioning must be checked once the whole
installation has been completed.
4° - In order to comply with the limits defined by the EN 12453 norm, if
the peak force is higher than the limit of 400N set by the norm, it is
necessary to use an active obstacle detection system on the whole
height of the gate (up to a maximum of 2,5m) - The photocells in
this case must be apply externally between the colums and internally
for all the race of the mobil part every 60÷70cm for all the height of
the column of the gate up to a maximum of 2,5m (EN 12445 point
7.3.2.1). example: column height 2,2m => 6 copies of photocells -
3 internal and 3 external (better if complete of syncronism feature).
N.B.: The system must be grounded
Data described by this manual are only Indicative and ALLMATIC reserves
to modify them at any time. Install the system complying with current
standards and regulations.
8 / 32
CHECKING BEFORE THE INSTALLATION
!! THE GATE SHALL MOVE FRICTIONLESS !!
Note: Gate features must be uniformed with the standards and laws in
force. The door/gate can be automated only if it is in a good condition and
its conditions comply with the EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in accordance
with EN 12453 norm (for instance; by preventing the operation of the
motor when the pedestrian opening is opened, by installing a safety
microswitch connected with the control panel).
- Besides the electrical or mechanical limit switches available on the
operators, there must be, on both ends of the installation, a fixed
mechanical stopper which stop the gate in the unlikely event of ill
functioning of limit swithces on the operators. For this reason the fixed
mechanical stopper must be of an adeguate size to withstand the static
and kinetic forces generated by the gate.
The guide must be provided with two mechanical stops at its ends.
- Gate columns shall have anti-derailment guides on their top, to avoid the
unintentional gate release.
Parts to install meeting the EN 12453 standard
Skilled persons
COMMAND TYPE
(out of public
area*)
with manned
A
operation
with visible impulses
C or E
(e.g. sensor)
with not visible
impulses
C or E
(e.g. remote control
device)
automatic
C and D, or E
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated).
B: Key selector with manned operation.
C: Adjustable power of the motor.
D: Safety strips and/or other safety devices to keep thrust force within the limits of
EN12453 regulation - Appendix A.
E: Photocells.

ELECTRICAL CONNECTIONS

To correctly connect the gearmotor to the control unit, follow the table below:
DESCRIPTION
COLOUR
PHASE 1 Black
PHASE 2 Brown
COMMON Grey or light blue
GROUND Yellow / Green
GROUND CONNECTION
The system must be grounded.
Use the predisposed clamp, connected to the yellow / green cable, to
connect the gearmotor to the ground system.
MAINTENANCE
To be carried out exclusively by skilled persons after the power supply to
the motor has been interrupted.
Periodically, when the gate is standstill, clean and keep the guide free from
stones and dirt.
6-1624804
USE OF THE CLOSING
Skilled persons
Unrestricted use
(public area)
B
non possibile
C or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
rev.7
20/01/2020

Publicité

Table des Matières
loading

Table des Matières