To aid in cleaning, wherever possible, the venting system should include a tee with clean out attached
to the flue collar on the stove.
Masonry Chimney
When venting into a masonry chimney, the pellet pipe can terminate just inside the chimney
.However, it is recommended to run the pellet pipe to the top of the chimney.
Fireplace
When venting into a fireplace chimney, the pellet pipe can terminate just above the damper.
However, it is recommended to run the pellet pipe to the top of the chimney.
Vertical
If the length of pipe exceeds 15 feet, 4 inch pipe rather than 3 inch vent pipe should be used.
Mobile Home Installations
The following are required for installation of the STOVE in mobile homes.
1) Connecting the STOVE to outside combustion air is optional, except in mobile home installations
and when required by local building codes. The stove's air intake will accept 3" ID pipe to
accommodate outside air installations. The air intake on the exterior of the home should always be
located substantially below the flue termination and terminate with a cover to keep out weather and
pests
2) The stove must be fastened to the floor using lag screws. The screws can be inserted through the
holes in the pedestal located behind the side doors
3) The stove must be grounded with a #8 or larger copper wire.
WARNING:
DO NOT INSTALL THIS STOVE IN A SLEEPING ROOM IN A MANUFACTURED HOME.