C. Regarding to the last
stage
4. Feeding not properly
A. too much wood pellet
and cannot burned in
time
B. The fire is off due to
little wood pellet can be
burned
5 After ignition the power
is off 15min later.
6 orange and lazy fire,
piled pellet, carbon on the
glass
7 The fire put out and
power is off automatically.
Feed unit is blocked.
There is the problem
about the connection
between motor and auger
No fuel in the hopper.
The level of feeding
speed is too high
The level of feeding
speed is too low
Pellet feeder unit is off or
pellet is too little.
30˚C temperature switch
breaks or the connection
wires of switch loose.
Not enough pressure in
the stove
Lack of air intake for
burning.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
low temperature switch
(30˚C) is wrong.
Set temperature is
reached
Check the auger is blocked or not.
Check the fasten screw between
auger and motor loose or not.
Or the auger might jump out
Fill the fuel into the hopper.
Adjust the combustion fan's speed
up
Adjust the combustion fan's speed
Down
Check the pellet feeder unit and
restart.
Check the connection wires or
change the 30˚C temperature
switch.
Adjust the combustion fan's speed
up
Clean the block in gate bar.
Check the door and window glass
gasket sealed or not.
Check the air intake pipe and
venting pipe blocked or not, and
clean it. Change to the big diameter
pipes if pipes are too long to affect
combustion.
Adjust the combustion fan's speed
up
Call the dealer to reset the program
Put fuel into the hopper. refer to (2)
Lower the speed of combustion fan
Cool the stove at least 1 hour then
operate again or change the low
temperature switch (30˚C).
"ECO" its normal, waiting, after the
temperature is blow set on, it will
automatically switch on again